Related Experiment Video
Updated: Aug 15, 2026

Utilizing Percutaneous Ventricular Assist Devices in Acute Myocardial Infarction Complicated by Cardiogenic Shock
Published on: June 12, 2021
Intra-Aortic Balloon Pump: Overall and Temporal Trends of Comparative Effectiveness in a National Registry
Ben Cohen1,2, Eran Kalmanovich2,3, Leor Perl1,2
1Cardiology Department, Belinson Hospital, Rabin Medical Center, Petah Tikva, Israel.
Background:
Although the latest studies failed to prove the benefit of routine intra-aortic balloon pump (IABP) use in patients with acute myocardial infarction (MI) presenting with cardiogenic shock, the benefit of IABP utilization in selected cases in "real world" practice is unknown.
Aims:
We sought to follow temporal trends in IABP use in a real-world cohort of acute coronary syndrome (ACS).
Methods:
We evaluated IABP utilization and patient outcomes from the Acute Coronary Syndrome in Israel Survey (ACSIS) between the years 2000 and 2021. Temporal trends and outcomes with IABP at two time periods were set: early (before 2012) and late (after 2012).
Results:
Out of 18,662 ACS patients, 3.7% received IABP. The rate of IABP use was 4.5% in the early period and decreased to ~2.5% in the late period (p < 0.001). Patients treated with IABP in the early period had more frequently reduced ejection fraction (64.5% vs. 53.2%, p < 0.01) and presented mostly with ST-elevation MI (71.0% vs. 62.4%, p = 0.04). Cardiogenic shock on admission and in-hospital occurred equally in both periods (14.6% vs. 17.1%, p = 0.66; 42.8% vs. 41.9%, p = 0.90, respectively). Thirty-day mortality and MACE were comparable between time periods (28% vs. 30.7%, p = 0.547; 43.6% vs. 44.1%, p = 0.978, respectively) however bleeding complications were significantly higher in the later period (4.8% vs. 11.2%, p = 0.04).
Conclusions:
Our real-world ACS data demonstrated a 50% reduction in the utilization of IABP among acute MI patients in the last decade. A comparable poor prognosis with IABP across time periods, suggest sustainable worse outcome in routine albeit selective clinical practice.
Related Concept Videos
Pulse
Pulse Rate and its Significance
Pulse rate, often measured in beats per minute (bpm), reflects the heart rate (HR), which is influenced by numerous factors such as stress, physical activity, and hormonal changes. A normal resting adult pulse rate falls between...
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Assessment of blood pressure in brachial artery(two-step method)
Pulse
The pulse serves as a clinical indicator...
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above the...
Cardiovascular System Abnormal Findings I: Inspection and Palpation
Abnormal findings observed during an inspection