Related Experiment Video
Updated: May 8, 2025

Experimental System of Solar Adsorption Refrigeration with Concentrated Collector
Published on: October 18, 2017
R290-Hydrofluoroolefin based low global warming potential refrigerant mixtures for room air conditioner: An energy,
Saji Raveendran Padmavathy1, Joseph Sekhar Santhappan2, Rajendran Prabakaran3
1Department of Mechanical Engineering, Builders Engineering College, Nathakadaiyur, Kangayam, Tirupur, Tamil Nadu, 638 108, India. sajivins@rediffmail.com.
Abstract:
Among the numerous residential appliances, window or split air conditioners are the most prevalent. The hydrochlorofluorocarbon and hydrofluorocarbon refrigerants used in those systems are causing a serious threat to the environment. In this study, R290-hydrofluoroolefin (HFO) mixtures are proposed as replacements for high-GWP substances (R410A and R22) in window air conditioning (WAC) units. Low-flammability alternatives like R290-R1234yf (50:50 and 60:40 by mass) and R290-R1234ze(E) (50:50 and 60:40 by mass) mixtures were considered promising refrigerants for this study. Using the REFPROP 10.0 refrigerant database and MATLAB-based mathematical modelling, the energy and exergy performance of a WAC unit with proposed and existing refrigerants was investigated. The results demonstrated that R290-HFO mixers performed well, with coefficients of performance that were 5.1-11.9% and 10.8-17.0% higher than those of R22 and R410A, respectively. In a similar fashion, the exergy efficiency of the WAC system increased by 3.1% to 6.2%, with reductions in total exergy degradation and power consumption of 7.1% to 12.2% and 5.1% to 10.1%, respectively. An assessment of the total equivalent warming impact revealed that the use of R290-HFO compounds results in CO2 emissions that are between 7.1 and 12.2% less than those of R22. Mini or microchannel heat exchangers for conventional evaporators and condensers can further decrease the predicted refrigerant change quantity for these mixtures, keeping it well below the IEC 60335-2-89 limit for flammable refrigerants.
Related Concept Videos
Refrigerators and Heat Pumps
A household refrigerator removes heat from...
Hess's Law
Free Energy Changes for Nonstandard States
where R is the gas constant (8.314 J/K·mol), T is the absolute temperature in kelvin, and Q is the reaction quotient. This equation may be used to predict the spontaneity of a process under any given set of conditions.
Reaction Quotient...
Efficiency of The Carnot Cycle
Turbulent Flow: Problem Solving
Temperature is a key factor in CO2 solubility. In this case, the CO2 gas and the liquid are cooled to 20°C. Lower temperatures...
Radical Halogenation: Thermodynamics

