First Reported Case of Hemoglobin Graz in the United States: Implications for Misleading Hemoglobin A1c Results
Luke Miller1, Yaniv Maddahi1, Matthew Shelly1
1Lewis Katz School of Medicine, Temple University, Philadelphia, PA 19140, USA.
Routine serum studies in a female patient with sustained prediabetic glycated hemoglobin A1c (HbA1c) levels, controlled on metformin, yielded an unexpected finding: an elevated HbA1c value of ≥14.9% (≥139 mmol/mol) (normal reference range, <5.7% to <39 mmol/mol). Estimated average glucose (EAG) (normal reference range, <126 mg/dL to <7 mmol/L) is a linearly corresponding blood glucose value calculated from HbA1c measurements that reflects the average glycemic status over the preceding 3 months. Caution must be used when the EAG provided by the HbA1c does not align with blood glucose values obtained around the same period. Our patient carries a rare heterozygous pathogenic variant affecting the β subunit called hemoglobin Graz (Hb Graz), characterized by a histidine for leucine substitution, resulting in clinically silent Hb abnormalities. Individuals without diabetes carrying the Hb Graz pathogenic variant exhibit significantly higher HbA1c values when analyzed by high-performance liquid chromatography. Alternative methods of quantifying glycemic control are suggested if the possibility of a confounding variable exists, such as when a HbA1c-blood glucose mismatch occurs or unexplainable HbA1c levels are detected.
Routine serum studies in a female patient with sustained prediabetic glycated hemoglobin A1c (HbA1c) levels, controlled on metformin, yielded an unexpected finding: an elevated HbA1c value of ≥14.9% (≥139 mmol/mol) (normal reference range, <5.7% to <39 mmol/mol). Estimated average glucose (EAG) (normal reference range, <126 mg/dL to <7 mmol/L) is a linearly corresponding blood glucose value calculated from HbA1c measurements that reflects the average glycemic status over the preceding 3 months. Caution must be used when the EAG provided by the HbA1c does not align with blood glucose values obtained around the same period. Our patient carries a rare heterozygous pathogenic variant affecting the β subunit called hemoglobin Graz (Hb Graz), characterized by a histidine for leucine substitution, resulting in clinically silent Hb abnormalities. Individuals without diabetes carrying the Hb Graz pathogenic variant exhibit significantly higher HbA1c values when analyzed by high-performance liquid chromatography. Alternative methods of quantifying glycemic control are suggested if the possibility of a confounding variable exists, such as when a HbA1c-blood glucose mismatch occurs or unexplainable HbA1c levels are detected.
Related Concept Videos
Blood Transfusion and Agglutination
History
The history of blood transfusion dates back to the 17th century, when early attempts were made in animals. In 1818 James Blundell, a British doctor, performed the first successful human blood transfusion. Later in 1900, Karl...
Hemoglobin
When all four heme groups are bound to oxygen, the resulting molecule is called oxyhemoglobin. As a result, arterial blood...
Rh Blood Group
Gene Families
Occasionally these regions can be adapted to take on new roles within the organism, becoming novel genes...
Blood Transfusion
Blood Transfusion Overview
A blood transfusion is a medical procedure used to replace blood lost due to injury, surgery, or to treat conditions such as anemia or cancer. During a transfusion, donor blood is...
Oxygen Transport in the Blood