Effects of Different Crystallization Protocols on Marginal Gap of Lithium Disilicate Single Crowns: SEM Analysis
Alon Shadur1, Joseph Nissan1, Diva Lugassy2
1Department of Oral Rehabilitation, The Maurice and Gabriela Goldschleger School of Dental Medicine, Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv 6997801, Israel.
Abstract:
Objective: In everyday dentistry, lithium disilicate is a valid option for single-fix partial dentures, and this material crystallization process is available with two protocols: long and short. This study's aim was to assess the effects of these two different crystallization protocols, long and short, on the marginal gap of lithium disilicate single crowns. Methods: A total of 24 abutment plastic teeth were scanned using an intra-oral scanner. For each plastic tooth, an identical pair of lithium disilicate crowns was milled (a total of 48 crowns) by a four-axis machine. Each paired sample was categorized into two groups: long crystallization (24 crowns) and short crystallization (24 crowns). To assess precision, each unit's marginal gap (including abutments and crowns) was meticulously measured at four specified regions using a scanning electron microscope. A Kolmogorov-Smirnov test performed on the study variables indicated a normal distribution (p > 0.05), and it was followed by independent t-tests (α = 0.05). Results: For the long crystallization group, the mean total marginal gap values were 42.91 ± 9.67 μm, and for the short crystallization group, the values were 43.25 ± 8.14 μm, with no significant difference between the groups (p = 0.894). In addition, no significant differences were found between the groups regarding the mean marginal gap measurements for all four surfaces (distal (p = 0.310), mesial (p = 0.732), palatal (p = 0.655), and buccal (p = 0.535)). Conclusions: Both the long and short crystallization methods used for lithium disilicate single crowns demonstrated marginal gap values of less than 120 μm, which are within the clinically acceptable range, with no significant differences across any parameters between the two groups. Regarding the marginal gap value, it is recommended to use the short crystallization protocol as it is more time-efficient.
More Related Videos
11:03Nanoscale Characterization of Liquid-Solid Interfaces by Coupling Cryo-Focused Ion Beam Milling with Scanning Electron Microscopy and Spectroscopy
Published on: July 14, 2022
07:42Quasistatic Mechanical Testing for Computer-Aided Design and Manufacturing Occlusal Veneers Cemented to Milled Dentin Analog Material
Published on: December 20, 2024
Related Concept Videos
Crystal Field Theory - Octahedral Complexes
To explain the observed behavior of transition metal complexes (such as colors), a model involving electrostatic interactions between the electrons from the ligands and the electrons in the unhybridized d orbitals of the central metal atom has been developed. This electrostatic model is crystal field theory (CFT). It helps to understand, interpret, and predict the colors, magnetic behavior, and some structures of coordination compounds of transition metals.
CFT focuses on...
Crystal Field Theory - Tetrahedral and Square Planar Complexes
Crystal field theory (CFT) is applicable to molecules in geometries other than octahedral. In octahedral complexes, the lobes of the dx2−y2 and dz2 orbitals point directly at the ligands. For tetrahedral complexes, the d orbitals remain in place, but with only four ligands located between the axes. None of the orbitals points directly at the tetrahedral ligands. However, the dx2−y2 and dz2 orbitals (along the Cartesian axes) overlap with the ligands less than the dxy,...
Imperfections in Crystal Structure: Point, Line and Plane Defects
Imperfections in Crystal Structure: Stoichiometric Point Defects
Imperfections in Crystal Structure: Non-Stoichiometric Defects