Related Experiment Video
Updated: May 8, 2025

Rab10 Phosphorylation Detection by LRRK2 Activity Using SDS-PAGE with a Phosphate-binding Tag
Published on: December 14, 2017
Activation Energy of SDS-Protein Complexes in Capillary Electrophoresis with Tetrahydroxyborate Cross-Linked Agarose
Dániel Sárközy1, András Guttman1,2
1Horváth Csaba Memorial Laboratory of Bioseparation Sciences, Research Center for Molecular Medicine, Faculty of Medicine, Doctoral School of Medicine, University of Debrecen, 4032 Debrecen, Hungary.
Abstract:
Hydrogels like agarose have long been used as sieving media for the electrophoresis-based analysis of biopolymers. During gelation, the individual agarose strands tend to form hydrogen-bond mediated double-helical structures, allowing thermal reversibility and adjustable pore sizes for molecular sieving applications. The addition of tetrahydroxyborate to the agarose matrix results in transitional chemical cross-linking, offering an additional pore size adjusting option. Separation of SDS-proteins during gel electrophoresis is an activated process defined by the interplay between viscosity, gelation/cross-link formation/distortion, and sample conformation. In this paper, the subunits of a therapeutic monoclonal antibody were separated by capillary SDS agarose gel electrophoresis at different temperatures. The viscosity of the separation matrix was also measured at all temperatures. In both instances, Arrhenius plots were used to obtain the activation energy values. It was counterintuitively found that larger SDS-protein complexes required lower activation energies while their low-molecular-weight counterparts needed higher activation energy for their electromigration through the sieving matrix. As a first approximation, we considered this phenomenon the result of the electric force-driven distortion of the millisecond range lifetime reticulations by the larger and consequently more heavily charged electromigrating molecules. In the meantime, the sieving properties of the gel were still maintained, i.e., they allowed for the size-based separation of the sample components, proving the existence of the reticulations. Information about the activation energy sheds light on the possible deformation of the sieving matrix and the solute molecules. In addition, the activation energy requirement study helped in optimizing the separation temperature, e.g., with our sample mixture, the highest resolution was obtained for the high-molecular-weight fragments, i.e., between the non-glycosylated heavy chain and heavy-chain subunits at 25 °C (lower Ea requirement), while 55 °C was optimal for the lower-molecular-weight light chain and non-glycosylated heavy chain pair (lower Ea requirement). Future research directions and possible applications are also proposed.
Related Concept Videos
SDS-PAGE
A variation of gel electrophoresis, termed polyacrylamide gel electrophoresis (PAGE), is commonly used for separating proteins according to their molecular size by passing them through a polyacrylamide gel. Because of the varying charges associated with amino acid side chains, PAGE can be used to separate intact...
DNA Agarose Gel Electrophoresis
Gel extraction follows five major steps: running gel electrophoresis to separate fragments, isolating the individual bands, extracting DNA from those bands, and removing the dye and salts from the extracted mixture to obtain pure DNA.
In cloning experiments, both the insert and vector DNA...
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
Capillary Electrophoresis: Instrumentation
Two-dimensional Gel Electrophoresis
The first dimension separation uses the isoelectric focusing or IEF technique performed on immobilized pH gradient (IPG) strips that separate proteins according to their isoelectric points.
Biological samples, such...

