Accuracy and Reliability of Grip Strength Measurements: A Comparative Device Analysis
Pascale Gränicher1,2, Yael Maurer1,3, Jörg Spörri1,4
1University Center for Prevention and Sports Medicine, Balgrist University Hospital, University of Zurich, CH-8008 Zurich, Switzerland.
Abstract:
Background: Grip strength is widely used as a surrogate parameter for functional status. The current gold standard, the JAMAR® Hydraulic Dynamometer (JAMAR® Hydraulic), presents challenges for individuals with painful finger joints or low grip strength. Therefore, the objective of this observational study was to assess comparability across the JAMAR® Smart, the Martin Vigorimeter and the gold standard. Additionally, the intrasubject and intersession reliability of all three devices were examined, which are essential for quality control before generating normative data. Methods: Forty healthy participants (aged 37.0 ± 11.3 years) were included, and a subset of 20 participants was randomly selected for retesting. Grip strength testing involved five attempts per measurement device. Results: Intrasubject reliability was excellent (ICC3,1: 0.91-0.97), and a strong correlation (ICC3,1: 0.90-0.98) was found between the first attempt and the best of five as well as between the best of two or three attempts and the best of five, demonstrating robust reliability across multiple measures. Intersession reliability was good to excellent (ICC3,1: 0.85-0.97) across all three devices, which was confirmed by Bland-Altman analysis. The PCC (r) revealed moderate to very strong agreement with the current gold standard JAMAR® Hydraulic (r = 0.68-0.98), with increased differences between the Martin Vigorimeter and the JAMAR® Hydraulic measurements, particularly at low and high values. Conclusions: The proposed devices are suitable for test-retest analysis with 2-3 attempts. Despite high correlations between all three devices, the diverging levels of agreement between the Martin Vigorimeter and the established gold standard warrant caution against using these devices interchangeably.
More Related Videos
08:40Isokinetic Robotic Device to Improve Test-Retest and Inter-Rater Reliability for Stretch Reflex Measurements in Stroke Patients with Spasticity
Published on: June 12, 2019
07:22Measuring the Motor Aspect of Cancer-Related Fatigue using a Handheld Dynamometer
Published on: February 20, 2020
Related Concept Videos
Uncertainty in Measurement: Reading Instruments
Accuracy and Precision
Statistical Analysis: Overview
One of the most commonly used statistical quantifiers is the mean, which is the ratio between the sum of the numerical values of all results and the...
Instrument Calibration
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
Accuracy and Precision
Non-destructive Tests for Concrete Strength