Related Experiment Video
Updated: Jun 12, 2025

Three Different Protocols of Corneal Collagen Crosslinking in Keratoconus: Conventional, Accelerated and Iontophoresis
Published on: November 12, 2015
Postoperative corneal remodeling after corneal allograft intrastromal ring segment (CAIRS) implantation for
Burcu Yakut1, Cafer Tanriverdi2, Fatma Feyza Nur Keskin Perk2
1Department of Ophthalmology, Haseki Training and Research Hospital, Istanbul, Turkey.
Objectives:
To demonstrate corneal remodeling after corneal allograft intrastromal ring segment (CAIRS) with an anterior-segment optical coherence tomography (AS-OCT).
Design:
A prospective observational single-center study.
Methods:
This observational study included keratoconus patients who underwent CAIRS implantation into a stromal tunnel. Topographical, refractive, and visual changes were obtained from the patient records. Epithelial thickness (ET), anterior stromal thickness (AST), allograft corneal ring thickness (ACRT), and posterior stromal thickness (PST) were measured on the first day and 1, 3, 6, and 12 months postoperatively using AS-OCT.
Results:
The study included 35 eyes of 27 patients with advanced keratoconus. The mean keratometry decreased from 48.26 ± 4.78 D to 44.50 ± 4.42 D at 1-year postoperatively ( P = 0.004), mean corrected distance visual acuity increased from 0.29 ± 0.18 to 0.70 ± 0.24 ( P < 0.001), and spherical equivalent (SE) decreased from -6.94 ± 4.32 D to -1.44 ± 4.44 D ( P < 0.001). The mean AST decreased by 17.39 ± 5.78 µm in the postoperative 1 st month compared to 1 st day after surgery ( P = 0.040). No statistically significant variations were observed in AST after the first month. There was no statistically significant difference in the mean ET, ACRT, and PST measurements between follow-up times. Significant negative correlations were found between SE change and ET (r = -0.543, P = 0.023) and between K1 change and ACRT (r = -0.548, P = 0.008).
Conclusion:
CAIRS is an effective treatment method to improve visual acuity and keratometry measurements and does not cause significant changes in graft thickness or recipient corneal epithelial and stromal thicknesses during the 1-year follow-up period. The observed correlations between SE, keratometry, and corneal thickness suggest that epithelial and stromal remodeling play crucial roles in postoperative outcomes of CAIRS.
More Related Videos
05:46Author Spotlight: Advancements in Refractive Surgical Correction for Presbyopia and Exploring Postoperative Visual Acuity
Published on: September 20, 2024
07:51Full-Field Optical Coherence Microscopy for Histology-Like Analysis of Stromal Features in Corneal Grafts
Published on: October 21, 2022