Related Experiment Video
Updated: May 8, 2025

Scanning Electron Microscopic Evaluation of Surface Defects of Remover Retreatment File After Single and Multiple Uses
Published on: October 11, 2024
Smear layer removal comparing conventional irrigation, passive ultrasonic irrigation, EndoActivator System, and a new
Bruna Fernanda Alionço Gonçalves1, Divya Reddy2, Ricardo Machado3
1Department of Endodontics, School of Health and Biosciences, Pontifical Catholic University of Paraná -PUC/PR, Curitiba, Paraná, Brazil.
Aim:
This study evaluated the smear layer removal provided by conventional, sonic, and ultrasonic irrigation techniques.
Methodology:
Forty extracted human mandibular first premolars were selected and instrumented using the ProTaper Next System files and 2.5% sodium hypochlorite. Afterward, they were divided into 4 groups (n. 10) according to the irrigation technique used to perform the final irrigation with a chelating solution (17% EDTA): conventional irrigation (CI), passive ultrasonic irrigation (PUI), EndoActivator System (EAS), and Perfect Clean System (PCS). The smear layer removal was determined through a score after evaluating scanning electron microscope images (1.000x) obtained at 1, 5, 8, and 12mm from the working length (WL). Statistical analyses were carried out by the Kruskal-Wallis and Dunn's tests with a significance level of 5% (P < 0.05).
Results:
All irrigation techniques were unable to promote an effective smear layer removal at 1mm from the WL in comparison with the other locations (P < .05). At 5, 8, and 12mm from the WL, no statistically significant differences were observed among CI, PUI, EAS, and PCS (P > 0.05). At 12mm from the WL, statistically significant differences were only identified after comparing PCS and CI (P < .05).
Conclusion:
The smear layer removal was only efficient at 5, 8, and 12 from the WL with no significant statistical differences among CI, PUI, EAS, and PCS (P > 0.05).