Diagnostic criteria for temporomandibular joint osteoarthritis using standardized uptake value in single-photon
Jae-Young Kim1, Chaeyeon Lee1, Young Long Park2
1Department of Oral and Maxillofacial Surgery, Yonsei University College of Dentistry, Gangnam Severance Hospital, 211 Eonju-ro, Gangnam-gu, Seoul, 06273, Republic of Korea.
Abstract:
This study aimed to investigate the cutoff values of standardized uptake values (SUVs) and their accuracy using single-photon emission computed tomography-computed tomography (SPECT-CT) for temporomandibular joint (TMJ) osteoarthritis (OA) based on magnetic resonance imaging (MRI) and clinical examination. We included 106 joints of 53 patients with TMJ OA. SUVmax and SUVpeak of each TMJ was measured. SUVref was set as the SUV at the clivus. The diagnostic performance, including sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy, were evaluated. SUVmax was 5.15, with a sensitivity of 59.375, specificity of 100.000, PPV of 100.000, NPV of 61.765, and accuracy of 75.472. The cutoff value for SUVpeak was 3.635, with sensitivity of 56.250, specificity of 100.000, PPV of 100.000, NPV of 60.000, and accuracy of 73.585. SUVmax was 3.286 ± 0.780 and 6.623 ± 3.442 in the non-OA and OA groups, respectively (p < 0.001). SUVpeak was 2.324 ± 0.688 and 4.913 ± 2.749 in the non-OA and OA groups, respectively (p < 0.001). SPECT-CT can be helpful for the diagnosis of patients clinically suspected of having OA. It is also recommended that clinicians keep in mind that patients with SUVmax values higher than the cutoff value should be managed with a higher possibility of OA.
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Imaging Studies III: Computed Tomography