Feasibility study of 'Triple-Low' technique for coronary artery computed tomography angiography (CCTA)
Shaochuan Wang1, Zhengwen Sun1, Yihong Zeng1
1The Second Affiliated Hospital of Xiamen Medical College, Xiamen, China.
Abstract:
This study aims to explore the feasibility of applying the "Three-Low" technique (low injection rate, low iodine contrast volume, low radiation dose) in coronary CT angiography (CCTA). We prospectively collected data from 90 patients who underwent CCTA at our hospital between 2021 and 2024. The patients were randomly assigned to either the experimental group (n = 45) or the control group (n = 45). The experimental group parameters were as follows: injection rate of 3.5-4.0 ml/s, iodine contrast volume of 35-40 ml, tube voltage of 100 kVp, and tube current of 250 mA. The control group parameters were: injection rate of 4.5-5.0 ml/s, iodine contrast volume of 45-50 ml, tube voltage of 120 kVp, and tube current of 450 mA. Both groups received a high-concentration, non-ionic, water-soluble contrast agent (Iomeprol, 40 gl/100 ml). The heart rate of all patients was ≤ 70 bpm, and breath-hold scanning was performed after breathing training. The study compared the CT values of the left anterior descending artery, left circumflex artery, right coronary artery, and aorta, as well as background noise, signal-to-noise ratio (SNR), volumetric CT dose index, dose-length product, effective radiation dose, and total iodine dose between the two groups. In the control group, no cases of contrast extravasation occurred, while 6 cases of extravasation were observed in the experimental group (p = 0.026). There was no significant difference between the groups in terms of vascular image quality (mean vascular image quality score: experimental group 4.27 ± 0.62 vs. control group 4.24 ± 0.57, p > 0.05) or vascular motion artifact score (mean vascular motion artifact score: experimental group 4.20 ± 0.59 vs. control group 4.13 ± 0.55, p > 0.05). However, significant differences were found between the experimental and control groups in the CT values of the left anterior descending artery (experimental group: 571.31 ± 49.66 HU vs. control group: 449.20 ± 36.80 HU, p < 0.05), left circumflex artery (experimental group: 570.41 ± 49.98 HU vs. control group: 450.95 ± 39.27 HU, p < 0.05), right coronary artery (experimental group: 584.52 ± 53.70 HU vs. control group: 452.66 ± 40.67 HU, p < 0.05), aorta (experimental group: 624.91 ± 48.99 HU vs. control group: 465.36 ± 34.37 HU, p < 0.05), background noise (experimental group: 24.76 ± 1.97 vs. control group: 19.09 ± 1.69, p < 0.05), SNR (experimental group: 25.30 ± 1.81 vs. control group: 24.47 ± 1.75, p < 0.05), volumetric CT dose index (experimental group: 22.97 ± 1.47 mGy vs. control group: 50.53 ± 4.89 mGy, p < 0.05), dose-length product (experimental group: 363.68 ± 21.45 mGy·cm vs. control group: 782.41 ± 58.20 mGy·cm, p < 0.05), and effective radiation dose (experimental group: 5.09 ± 0.30 mSv vs. control group: 10.95 ± 0.81 mSv, p < 0.05).The results of the Fisher test indicated that the extravasation rate was significantly higher in the high injection rate group compared to the low injection rate group (P = 0.024). The "Three-Low" technique in CCTA imaging effectively reduces the incidence of contrast extravasation caused by high injection rates and decreases the radiation dose, making it a highly feasible option for clinical application and worthy of broader adoption.
More Related Videos
06:59Improved Registration of 3D CT Angiography with X-ray Fluoroscopy for Image Fusion During Transcatheter Aortic Valve Implantation
Published on: June 3, 2018
10:16Retrograde Perfusion and Filling of Mouse Coronary Vasculature as Preparation for Micro Computed Tomography Imaging
Published on: February 10, 2012
Related Concept Videos
Imaging Studies for Cardiovascular System V: CT
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...