Related Experiment Video
Updated: Jun 24, 2026

Computerized Dynamic Posturography for Postural Control Assessment in Patients with Intermittent Claudication
Published on: December 11, 2013
Validation of Devices for the Five Times Sit To Stand Test: Comparing Plantar Pressure and Head Motion Analysis with
Sanghyun Jee1, Chan Woong Jang2,3, Kyoungmin Park4
1Department of Rehabilitation Medicine, Rehabilitation Institute of Neuromuscular Disease, Gangnam Severance Hospital, Yonsei University College of Medicine, Seoul, Korea.
Purpose:
This study aims to evaluate a new method for the five times sit to stand test (FTSST), crucial for addressing frailty in an aging population. It utilizes a smart insole for plantar pressure analysis and a marker-less motion capture device for head height analysis.
Materials And Methods:
Thirty-five participants aged 50 years or older underwent FTSST assessment using three methods: manual measurement with a stopwatch (FTSST-M), plantar pressure analysis with smart insoles (FTSST-P), and head height analysis with a marker-less motion capture device (FTSST-H). Simultaneous measurements using three methods were done. Correlation between results of these methods were analyzed using intraclass correlation coefficient (ICC) and κ coefficient. Comprehensive clinical examinations were conducted with ethical approval.
Results:
Participants' mean scores for FTSST-M, FTSST-P, and FTSST-H were 2.43±1.20, 2.43±1.29, and 2.37±1.31, respectively. Correlations of the times and corresponding scores between FTSST-P and FTSST-M, as well as FTSST-H and FTSST-M, exceeded 0.9 (ICC and κ coefficients, p<0.001). Using an FTSST score of 3 or less to indicate vulnerability, the κ value for vulnerability classification between two measurements was 0.886 (p<0.001).
Conclusion:
This study showed strong correlation between FTSST results using smart insoles and marker-less motion capture, compared to conventional methods. These findings highlight the potential of these technologies for precise FTSST measurements, offering convenience and cost-effectiveness. Simultaneous use of these devices enables diverse analyses, enhancing our understanding of frailty.
More Related Videos
08:24Sit-to-stand-and-walk from 120% Knee Height: A Novel Approach to Assess Dynamic Postural Control Independent of Lead-limb
Published on: August 30, 2016
02:15Predictive Measurement for Windlass Change in Length and Selected Treatment Outcomes in Chronic Plantar Fasciitis
Published on: March 1, 2024