Related Experiment Video
Updated: Jun 4, 2025

Endoscopic Bilateral Nipple-sparing Mastectomy via a Single Axillary Incision with Immediate Pre-pectoral Implant-based Breast Reconstruction
Published on: May 17, 2024
Women with Breast Implants Have Higher Adjusted Abnormal Cardiac Testing and Coronary Angiography but Lower Coronary
Mohammad Reza Movahed1, Kyvan Irannejad2, Emma Venard3
1University of Arizona Sarver Heart Center, Tucson; College of Medicine, University of Arizona, Phoenix.
Background:
Breast implants interfere with myocardial perfusion imaging (single photon emission computed tomography) and echocardiographic windows, leading to increased false-positive results. To validate this concept, we hypothesized that patients with breast implants should have higher positive cardiac testing and coronary angiogram with lower percutaneous coronary intervention (PCI) rates compared with women without a breast implant.
Methods:
Using International Classification of Diseases, 10th Revision codes for breast implants, abnormal results of cardiac functional study, coronary angiogram, and PCIs, we evaluated any association between these parameters in adult women with breast implants utilizing the National Inpatient Sample database.
Results:
A total of 45,015 women had abnormal cardiac functional studies. A total of 1,871,335 women ages 18 years or older underwent coronary angiography. From those, 865,020 underwent PCI. Women with breast implants with abnormal cardiac functional tests were 10 years younger (55.06 vs 65.06 years, P < .001). Furthermore, the breast implant cohort had a higher adjusted abnormal cardiac functional study (odds ratio [OR] 1.78; 95% confidence interval [CI], 1.11-2.26; P = .02). Adult women with breast implants also had a significantly higher rate of adjusted coronary angiography (OR 1.3; 95% CI, 1.17-1.44; P < .001) but a lower rate of PCI (35.7% vs 46.2%, P < .001, unadjusted OR 0.65; 95% CI, 0.54-0.78; adjusted OR 0.79; 95% CI, 0.65-0.98; P = .01).
Conclusions:
Women with breast implants had higher adjusted positive cardiac functional studies, and a higher adjusted rate of coronary angiography but lower rates of PCI, consistent with our hypothesis that breast implant interference can increase abnormal cardiac testing, leading to an increase in the utilization of coronary angiography.
More Related Videos
06:39Novel Percutaneous Approach for Deployment of 3D Printed Coronary Stenosis Implants in Swine Models of Ischemic Heart Disease
Published on: February 18, 2020
06:03Integrating Augmented Reality Tools in Breast Cancer Related Lymphedema Prognostication and Diagnosis
Published on: February 6, 2020
Related Concept Videos
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Imaging Studies for Cardiovascular System V: CT
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion,...
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Imaging Studies for Cardiovascular System IV: CMRI