Single-use versus multiple-use endotracheal suction catheters flushed with chlorhexidine in mechanically ventilated
Mohamed H Eid1,2, Kevin Hambridge1, Pat Schofield1
1Faculty of Health, School of Nursing and Midwifery, University of Plymouth, Plymouth, UK.
Background:
Endotracheal suction catheters are often used multiple times during endotracheal suctioning procedures in resource-limited intensive care units (ICU). The impact of this practice on mechanically ventilated patients' outcomes remains unclear.
Aim:
The aim of this feasibility randomized controlled trial (fRCT) is to assess the feasibility and acceptability of single-use versus multiple-use endotracheal suction catheters flushed with chlorhexidine in mechanically ventilated ICU patients.
Study Design:
This study is a three-armed fRCT with an embedded qualitative study.
Results:
The trial involves three groups. One group includes endotracheal suctioning using a single-use catheter; the second group includes a multiple-use endotracheal suction catheter flushed with chlorhexidine and the control group includes a multiple-use endotracheal suction catheter flushed with normal saline. Sixty adult ICU patients (20 in each group) will be recruited, along with 12-16 ICU nurses delivering the interventions, and 12-16 patients' next-of-kin for semi-structured interviews. The study protocol has been approved by two ethics committees. Study recruitment will be conducted over an 8-month period with an expected start date of 12 April 2024.
Conclusion:
The feasibility outcome measures will be recruitment, retention, and follow-up measures as well as the identification of clinical outcomes such as Ventilator-Associated Pneumonia (VAP) using the modified clinical pulmonary infection score, and ICU length-of-stay.
Relevance To Clinical Practice:
This study will help ICU nurses to understand how different methods of endotracheal suctioning affects patients in ICUs with limited resources. The findings could influence clinical practice and improve patient outcomes.
More Related Videos
09:57A Protocol to Set Up Needle-Free Connector with Positive Displacement on Central Venous Catheter in Intensive Care Unit
Published on: July 13, 2019
09:36Halogenated Agent Delivery in Porcine Model of Acute Respiratory Distress Syndrome via an Intensive Care Unit Type Device
Published on: September 24, 2020
Related Concept Videos
Tracheostomy Suctioning II: Procedure
Tracheostomy Suctioning I: Pre-Procedural Steps
Equipment Required
First, gather all necessary equipment: a sterile suction catheter, a sterile disposable container, sterile gloves, a towel or...
Suctioning the Oropharyngeal Airway
After assembling the equipment, the nurse should practice hand hygiene and don appropriate PPE according to infection control guidelines to avoid the...
Suctioning the Nasopharyngeal Airway
Equipment Required
Hand hygiene
Hand washing...
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...