Related Experiment Video
Updated: May 12, 2026

High Precision Zinc Isotopic Measurements Applied to Mouse Organs
Published on: May 22, 2015
Interpret probability density functions and maximum entropy model for zinc removal in PRDC column by analyzing
Mehdi Asadollahzadeh1, Rezvan Torkaman2
1Nuclear Fuel Cycle Research School, Nuclear Science and Technology Research Institute, P.O. Box: 11365-8486, Tehran, Iran. mehdiasadollahzadeh@alumni.iust.ac.ir.
Abstract:
The research discussed in this paper focused on experimental data using a perforated rotating disc column to determine the factors that impact the distribution of drop sizes. A standard test system was utilized, consisting of zinc ions and D2EHPA extractant. When the rotor speed is increased, a majority of droplets display a smaller range of diameters, primarily because of decreased coalescence and increased breakup effects. This column examined how the extraction or stripping stages are influenced by the direction of mass transfer and changes in interfacial tension of the droplets. The findings indicated that the movement of zinc ions between the aqueous and organic phases alters the average droplet size, impacting the distribution of droplet sizes. During the extraction phase, smaller Sauter mean drop sizes were noted in comparison to the stripping phase. A statistical tool was being developed to forecast size distribution by analyzing the relationship between operational factors through the maximum entropy principle. Different probability density functions such as Normal, Lognormal, Gamma, Inverse Gaussian, and Weibull were explored for forecasting size distribution in statistical assessments. By utilizing the maximum entropy technique, the projected probability density function was identified as the most precise based on empirical data, suggesting strong alignment when utilizing this approach to anticipate drop size distribution in the perforated rotating disc column.
More Related Videos
11:18A Practical Guide on Coupling a Scanning Mobility Sizer and Inductively Coupled Plasma Mass Spectrometer (SMPS-ICPMS)
Published on: July 11, 2017
07:53Analysis of Complex Molecules and Their Reactions on Surfaces by Means of Cluster-Induced Desorption/Ionization Mass Spectrometry
Published on: March 1, 2020
Related Concept Videos
Extraction: Partition and Distribution Coefficients
For extracting a solute from an aqueous phase into an...
Precipitation and Co-precipitation
Extraction: Advanced Methods
Column Efficiency: Plate Theory
A higher number of theoretical plates signifies better column efficiency and improved separation capabilities. Plate height affects bandwidth and separation quality; it is inversely...
Column Efficiency: Rate Theory
During elution, a solute molecule experiences numerous transitions between stationary and mobile phases, exhibiting irregular residence times in...
Optimizing Chromatographic Separations
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...