Related Experiment Video
Updated: May 7, 2025

A Swin Transformer-Based Model for Thyroid Nodule Detection in Ultrasound Images
Published on: April 21, 2023
A novel method for intelligent operation and maintenance of transformers using deep visual large model DETR + X and
Xuedong Zhang1, Wenlei Sun2, Ke Chen3
1School of Intelligent Manufacturing Modern Industry, Xinjiang University, Urumqi, 830046, Xinjiang, China.
Abstract:
To achieve real-time monitoring and intelligent maintenance of transformers, a framework based on deep vision and digital twin has been developed. An enhanced visual detection model, DETR + X, is proposed, implementing multidimensional sample data augmentation through Swin2SR and GAN networks. This model converts one-dimensional DGA data into three-dimensional feature images based on Gram angle fields, facilitating the transformation and fusion of heterogeneous modal information. The Pyramid Vision Transformer (PVT) is innovatively adopted as the backbone for image feature extraction, replacing the traditional ResNet structure. A Deformable Attention mechanism is employed to handle the complex spatial structure of multi-scale features. Testing results indicate that the improved DETR + X model performs well in transformer state recognition tasks, achieving a classification accuracy of 100% for DGA feature maps. In object detection tasks, it surpasses advanced models such as Faster R-CNN, RetinaNet, YOLOv8, and Deformable DETR in terms of overall mAP50 scores, particularly demonstrating significant enhancements in small object detection. Furthermore, the Llava-7b model, fine-tuned based on domain expertise, serves as an expert decision-making tool for transformer maintenance, providing accurate operational recommendations based on visual detection results. Finally, based on digital twin and inference models, a comprehensive platform has been developed to achieve real-time monitoring and intelligent maintenance of transformers.
Related Concept Videos
Transformers in Distribution System
Distribution substation transformers come in various ratings and typically use mineral oil for insulation and cooling. To prevent moisture and air from entering the oil, some transformers use an inert gas like nitrogen to fill the...
Transformers with Off-Nominal Turns Ratios
Three-Winding Transformers
In the per-unit equivalent circuit of a grounded Y-Y three-phase...
Energy Losses in Transformers
There are four main reasons for energy losses in transformers.
The first cause can be the high resistance of the...
Instrument Transformers
Types Of Transformers
If the ratio of the number of turns in the secondary winding to that of the primary winding is greater than one, then the transformer is said to be a step-up transformer. In a step-up transformer, the voltage at the secondary winding is greater than the voltage applied at the primary winding.
However, if this ratio is less than one, the transformer is said to be a step-down...