Routine Collection of High-Resolution cryo-EM Datasets Using 200 KV Transmission Electron Microscope
Published on: March 16, 2022
High-resolution cryo-EM using a common LaB6 120-keV electron microscope equipped with a sub-200-keV direct electron
Hariprasad Venugopal1, Jesse Mobbs2,3, Cyntia Taveneau4
1Ramaciotti Centre for Cryo-Electron Microscopy, Monash University, Clayton, VIC, Australia.
Researchers demonstrate that standard 120-keV transmission electron microscopes (TEMs) with a lanthanum hexaboride (LaB6) source can achieve high-resolution cryo-electron microscopy (cryo-EM) using a direct electron detector (DED). This provides an affordable path to obtaining interpretable cryo-EM structures.
Area of Science:
- Structural Biology
- Microscopy Techniques
- Biophysics
Background:
- High-resolution cryo-electron microscopy (cryo-EM) typically necessitates expensive 200-300 keV cryo-transmission electron microscopes (cryo-TEMs).
- Recent advancements in sub-200 keV direct electron detector (DED) technology offer potential for more affordable cryo-TEMs.
- Current 100 keV cryo-EM imaging relies on field emission gun (FEG) sources.
Purpose of the Study:
- To investigate the feasibility of upgrading standard 120 keV TEMs with a thermionic lanthanum hexaboride (LaB6) source for high-resolution cryo-EM.
- To assess the performance of a sub-200 keV DED in conjunction with a LaB6 source for cryo-EM structure determination.
- To explore a cost-effective approach for obtaining interpretable cryo-EM structures.
Main Methods:
- Utilized a standard 120 keV TEM equipped with a thermionic LaB6 source.
- Integrated a sub-200 keV optimized direct electron detector (DED).
- Employed automated data collection using SerialEM with a side-entry cryo-holder.
Main Results:
- Achieved a 2.65 Å resolution reconstruction of apoferritin.
- Obtained a 4.33 Å resolution reconstruction of 64 kDa hemoglobin.
- Resolved an asymmetric 153 kDa membrane protein GPCR at 4.4 Å resolution.
Conclusions:
- Demonstrated that standard 120 keV TEMs with LaB6 sources can be upgraded for high-resolution cryo-EM.
- Showcased the potential for widely accessible and low-cost cryo-EM structure determination.
- Contributed to the democratization of cryo-EM technology for broader scientific application.
More Related Videos
09:25Do's and Don'ts of Cryo-electron Microscopy: A Primer on Sample Preparation and High Quality Data Collection for Macromolecular 3D Reconstruction
Published on: January 9, 2015
09:16Manual Blot-and-Plunge Freezing of Biological Specimens for Single-Particle Cryogenic Electron Microscopy
Published on: February 7, 2022
Related Concept Videos
Cryo-electron Microscopy
Electron Microscope Tomography and Single-particle Reconstruction
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...