Electrocardiographic marker of ventricular action potential triangulation (the simulation study)
Natalia V Arteyeva1, Oleg E Osadchii2
1Department of Cardiac Physiology, Institute of Physiology, Komi Science Center, Ural Branch, Russian Academy of Sciences, 50, Pervomayskaya st., Syktyvkar 167982, Russia.
Background:
The aim of this simulation was to examine the utility of a novel ECG-based index of cardiac action potential (AP) triangulation, the Tstart-to-Tpeak (TsTp) interval-to-JTstart (JTs) interval ratio, for assessment of changes in AP profile imposed through variations in the duration of the plateau phase and the phase 3 repolarization.
Methods:
ECGs were simulated using a realistic rabbit model based on experimental data. The AP plateau was measured at APD30, and the phase 3 was assessed as APD90-to-APD30 difference (AP durations at 90 % and 30 % repolarization, respectively). AP triangulation was quantified as (APD90-APD30)-to-APD30 ratio. The baseline durations of AP plateau and phase 3 were modified through (1) 50 % shortening, (2) 50 % to 100 % lengthening, and (3) concurrent, non-uniform lengthening in both the AP plateau and phase 3, replicating the long QT syndrome type 2 (LQT2) and type 3 (LQT3) models.
Results:
When simulating the isolated changes in either the AP plateau or the phase 3 durations, the (APD90-APD30)-to-APD30 ratios were the same for all model cells. The TsTp/JTs ratios calculated from the simulated ECGs closely approximated the (APD90-APD30)-to-APD30 ratios, despite the lead-to‑lead variability in TsTp and JTs intervals. When simulating the concurrent changes in AP plateau and the phase 3, the (APD90-APD30)-to-APD30 ratios were variable in cells from different layers across the ventricular wall. Nevertheless, the TsTp/JTs ratios were found to be within the range of the minimum-to-maximum values for the (APD90-APD30)-to-APD30 ratio.
Conclusions:
The TsTp interval-to-JTs interval ratio can serve as an electrocardiographic marker of cardiac AP triangulation.
Related Concept Videos
Electrocardiogram Fundamentals
An electrocardiogram (ECG) is a diagnostic tool for identifying cardiac conditions such as arrhythmias, conduction abnormalities, and myocardial ischemia.
Definition
An electrocardiogram (ECG) visualizes the heart's electrical activity by tracing the electrical movement associated with each heartbeat on a graph or monitor. As the heart beats, an electrical wave passes through it, correlating with the cardiac cycle events.
Parts of an ECG
An ECG utilizes electrodes on the skin...
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and...
Correlation between ECG and Cardiac Cycle
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...
Cardiac Action Potential
The cardiac action potential process involves a series of phases characterized by the movement of ions across the cardiac cell membranes, leading to the depolarization and repolarization of the cardiac myocytes.
Ionic Basis of Cardiac Action Potentials


