Related Experiment Video
Updated: Jun 4, 2025

A Novel Rescue Technique for Difficult Intubation and Difficult Ventilation
Published on: January 17, 2011
Predictive value of cough peak flow for successful extubation in mechanically ventilated patients after craniotomy: a
Jianfang Zhou1, Hong-Liang Li2, Xu-Ying Luo1
1Department of Critical Care Medicine, Beijing Tiantan Hospital, Capital Medical University, Beijing, Beijing, China.
Objectives:
The purpose of this study was to evaluate the predictive value of the cough peak flow (CPF) for successful extubation in postcraniotomy critically ill patients.
Design:
This was a single-centre prospective diagnostic study.
Setting:
The study was conducted in three intensive care units (ICUs) of a teaching hospital.
Participants:
Postcraniotomy patients who were 18 years or older, stayed in ICU for more than 24 hours and underwent mechanical ventilation for more than 24 hours were eligible for the study. Patients were excluded if one of the following was present: no extubation attempt during the ICU stay; underwent tracheostomy without extubation attempt; pregnant or lactating women; enrolled in other clinical trials; declined to participate in the study. A total of 4879 patients were screened and 1037 were eligible for the study, among whom 785 were included in the study.
Outcome Measures:
CPF, including involuntary (CPF-invol) and voluntary CPF (CPF-vol), were measured before extubation. The area under the receiver operating characteristic curve (AUC) was calculated to explore the diagnostic accuracy of CPF in predicting successful extubation.
Results:
There were 641 successful extubation cases (81.7%). The AUC of CPF-invol for predicting successful extubation was 0.810 (95% CI 0.766 to 0.854), with a cut-off value of 63.2 L/min, a sensitivity of 87.4% and a specificity of 66.7%. For conscious patients, the AUC of CPF-invol for the prediction of successful extubation was 0.849 (95% CI 0.794 to 0.904), with a cut-off value of 63.2 L/min and the AUC of CPF-vol was 0.756 (95% CI 0.696 to 0.817), with a cut-off value of 68.2 L/min.
Conclusions:
The CPF was much higher in patients with successful extubation than that in patients with failed extubation. CPF might be valuable for the prediction of extubation outcomes in postcraniotomy critically ill patients. Multicentre studies could be carried out to further validate the results of this study.
Trial Registration Number:
NCT04000997.
More Related Videos
03:58Author Spotlight: Advancing Awake Nasotracheal Intubation with Flexible Video Rhino-Laryngoscopes
Published on: August 2, 2024
05:39Author Spotlight: A Non-Intubated Video-Assisted Thoracoscopic Surgery with Multimodal Analgesia and Sevoflurane Inhalation Anesthesia
Published on: May 26, 2023
Related Concept Videos
Endotracheal Tube Extubation
Procedure
Extubation removes the endotracheal tube (ETT) from the patient on mechanical ventilation. It requires a well-coordinated, multidisciplinary approach involving physicians, nurses, respiratory therapists, and other healthcare professionals....
Endotracheal Intubation II: Nursing Management
1. Nursing Care of Patients Before Intubation
Before the endotracheal intubation procedure, nurses play an essential role in ensuring the process goes smoothly. The nurses must be familiar with intubation...
Tracheostomy Decannulation
Description of the Procedure
Decannulation refers to the permanent removal of the tracheostomy tube, signaling the resolution of the condition that initially necessitated the tracheostomy. The process requires a well-coordinated interplay between...
Acute Respiratory Failure-V
Ensure that patients are monitored continuously for their response to therapy, including changes in...
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...