In Vitro Thrombosis Test for Ventricular Assist Devices
Published on: March 21, 2025
Altered thrombin generation with prothrombin complex concentrate is not detected by viscoelastic testing: an in vitro
Nikolaus Hofmann1, Herbert Schöchl2, Johannes Zipperle3
1Medical University of Vienna, Department of Anaesthesia, Intensive Care Medicine and Pain Medicine, Division of General Anaesthesia and Intensive Care Medicine, Vienna, Austria; Ludwig Boltzmann Institute for Traumatology, The Research Center in Cooperation with AUVA, Vienna, Austria.
Viscoelastic testing (VET) parameters like clotting time (CT) and activated clotting time (ACT) do not accurately reflect thrombin generation. Prolonged CT or ACT should not trigger prothrombin complex concentrate (PCC) administration for augmenting thrombin generation.
Area of Science:
- Coagulation science
- Hemostasis research
- Critical care medicine
Background:
- Current bleeding guidelines recommend viscoelastic testing (VET) for managing severe hemorrhage.
- VET parameters like clotting time (CT) and activated clotting time (ACT) may not fully represent procoagulant and anticoagulant interactions.
- Thrombin generation assays offer a more comprehensive view of hemostasis.
Purpose of the Study:
- To assess the ability of CT and ACT to indicate thrombin generation activity.
- To compare VET parameters with thrombin generation after blood dilution and prothrombin complex concentrate (PCC) administration.
Main Methods:
- Citrated whole blood from 13 healthy volunteers was diluted by 50% with crystalloid.
- Blood was spiked with four-factor prothrombin complex concentrate (4F-PCC).
- Thrombin generation was measured and compared with CT and ACT from four VET devices and standard coagulation tests.
Main Results:
- Blood dilution increased thrombin generation parameters (velocity index, peak height, endogenous thrombin potential).
- CT and ACT significantly prolonged after dilution on all VET devices.
- 4F-PCC addition did not affect CT or ACT but improved standard coagulation tests.
Conclusions:
- Thrombin generation increases after PCC spiking were not reflected by CT or ACT.
- Current treatment algorithms using prolonged CT or ACT to guide PCC administration are not supported.
- VET parameters may not be reliable indicators for augmenting thrombin generation with PCC.