Related Experiment Video
Updated: May 26, 2026

High-throughput and Comprehensive Drug Surveillance Using Multisegment Injection-Capillary Electrophoresis-Mass Spectrometry
Published on: April 23, 2019
The Impact of Triptorelin on Hormone Levels in Human and Its Metabolite Confirmation Using Liquid Chromatography-Ion
Navaporn Saardpun1,2, Cholsittapan Asawesna1, Seksun Kaewklam1
1National Doping Control Center (NDCC), Analytical Sciences and National Doping Test Institute (ANDI), Mahidol University, Bangkok, Thailand.
Abstract:
Triptorelin, a synthetic gonadotrophin-releasing hormone (GnRH), is mainly used in the clinical treatment of prostate cancer. The mechanism initially stimulates luteinizing hormone (LH) and testosterone secretion followed by suppression, resulting in a reduction in cancer progression. However, GnRHs are prohibited in doping control because of the indirect surge of LH and testosterone. Therefore, GnRH analog detection and confirmation are enforced by World Anti-Doping Agency (WADA) requirements. The effects of triptorelin on LH and endogenous steroid levels in urine and serum of five prostate cancer patients taking triptorelin for the first time were investigated and compared with leuprorelin. The samples were collected at 0.0 h, 3.0 h, 6.0 h, 1 month, and 3 months later after drug administration. The effect of triptorelin on LH levels was measured using a sandwich enzyme-linked immunoassay (ELISA). Testosterone and endogenous steroid levels were monitored using gas chromatography coupled with mass spectrometry (GC/MS). Triptorelin showed an advantage over leuprorelin on LH and testosterone suppression, which is preferable to use for prostate cancer treatment. In this study, triptorelin (5-10), a unique in vivo metabolite, was found in urine and serum and verified with synthetic triptorelin (5-10). The metabolite was analyzed using liquid chromatography combined with Orbitrap (LC-Orbitrap) and liquid chromatography coupled with ion trap/time-of-flight mass spectrometry (LC/MS-IT-TOF). When triptorelin levels are undetectable, the presence of triptorelin (5-10) in human urine can be used as evidence that triptorelin is being misused in doping control.
More Related Videos
10:13Author Spotlight: An Efficient Methodology to Confidently Differentiate and Characterize Fentanyl Analogs
Published on: November 8, 2024
08:56Detection of Regulated Ergot Alkaloids in Food Matrices by Liquid Chromatography-Trapped Ion Mobility Spectrometry-Time-of-Flight Mass Spectrometry
Published on: November 22, 2024