Related Experiment Video
Updated: Jun 3, 2025

Synthesis and Reaction Chemistry of Nanosize Monosodium Titanate
Published on: February 23, 2016
Cyclic Voltarefractometry of Single TiO2 Nanoparticles in Large Ensembles in Nonaqueous Electrolyte
Veronika K Laurinavichyute1, Shavkat Nizamov1, Vladimir M Mirsky1
1Nanobiotechnology Department of the Institute of Biotechnology, Brandenburg University of Technology Cottbus-Senftenberg, Universitaetsplatz 1, Senftenberg 01968, Brandenburg, Germany.
Abstract:
Single nanoparticle (NP) cyclic voltarefractometry (CVR), realized as wide-field surface plasmon resonance microscopy (SPRM) in combination with potential cycling, has been proposed and applied to the in situ study of TiO2 NPs. Electrochemical activity of TiO2 is mainly observed outside the electrochemical stability window of water. Therefore, the response of individual anatase (a-TiO2) and rutile (r-TiO2) NPs adsorbed on a gold layer was studied in 0.25 M LiClO4 acetonitrile solutions. The use of acetonitrile allows us to exploit a much wider potential window compared to water, while due to the almost identical refractive index (nD = 1.344 and 1.333 for acetonitrile and water, respectively), the conditions of the SPR are not changed. This greatly expands the variety of electrochemical reactions that can be studied by SPR techniques. Cyclic polarization of a-TiO2 and r-TiO2 NPs results in pronounced electrochemical and optical responses around -1.55 V and around -1.8 V vs Fc+/Fc, respectively. This specific optoelectrochemical response allows them to be distinguished from other NPs. Based on this difference in characteristic potentials, a mixture of a-TiO2 and r-TiO2 NPs can be analyzed by CVR as well. The proposed correction algorithm compensates for the drift in the SPRM background caused by the accompanying formation of insoluble compounds and separates the optical response of the NPs out of the background. The results obtained in the study of this complex system demonstrate the capabilities of the developed analytical method. The CVR can be applied to the quantitative analysis of many other types of NPs in nonaqueous solutions, providing information on the electrochemical properties of each individual particle on the electrode surface.
More Related Videos
Related Concept Videos
Voltammetric Techniques: Cyclic Voltammetry
Thermal and Photochemical Electrocyclic Reactions: Overview
Voltammetry: Overview
A voltammetric cell uses three electrodes: a working electrode, a reference electrode, and an auxiliary electrode. The redox reactions occur in the working...

