Related Experiment Video
Updated: May 2, 2026

Measurement of Pulse Propagation Velocity, Distensibility and Strain in an Abdominal Aortic Aneurysm Mouse Model
Published on: February 23, 2020
Yes-associated protein-based detection of acute type A aortic dissection and evaluation of therapeutic responses
Kai Zhu1,2, Hao-Xi Li3, Dong-Dong Wu4
1Department of Cardiovascular Surgery, Beijing Anzhen Hospital, Capital Medical University, Beijing, China.
Background:
Acute aortic dissection is a lethal cardiovascular emergency; early diagnosis is critically necessary. Novel serum biomarkers can potentially help in early detection and estimation of postoperative outcomes. Yes-associated protein (YAP) is a critical effector of the Hippo pathway, our aim was to explore the association between YAP and the diagnosis and prognosis of AD.
Methods:
We prospectively recruited 110 consecutive chest-pain patients [acute type A aortic dissection (ATAAD), n = 60; acute coronary syndrome (ACS), n = 50]. Blood samples were collected to determine levels of YAP and other serum biomarkers, and receiver operating characteristic curves (ROC) were constructed to assess the predictability in early diagnosis of AAD and postoperative major adverse events (MAEs).
Results:
YAP concentration was substantially elevated among ATAAD patients [3.45 (3.18, 3.63) vs. 2.44 (2.23, 2.59), P < 0.01]. Moreover, the white blood cell (WBC) count and plasma fibrin D-dimers were remarkably high among ATAAD patients [11.46 (9.57, 14.03) vs. 6.24 (5.10, 7.30), P < 0.01; 2,097.00 (998.75, 3,652.00) vs. 97.00 (67.25, 137.00), P < 0.01]. The serum YAP level held as a good predictive value in early diagnosis of ATAAD. The optimal cutoff value was 3.15 ng/ml, with an AUC of 0.94 (95% CI, 0.90-0.98, P < 0.01), sensitivity of 80% and specificity of 98%. The combined model of YAP, WBC count and D-Dimer exhibited an enhanced predictive power, with an AUC of 0.99 (95% CI, 0.98-1.00, P < 0.01). Serum YAP values at 12 h post-surgery provided the most accurate prediction of postoperative MAEs, with an optimal cutoff value of 3.60 ng/ml, an AUC of 0.89 (95% CI, 0.79-0.99, P < 0.01), and sensitivity and specificity of 88% and 82%, respectively.
Conclusions:
The serum YAP concentration is an early and sensitive serum bioindicator for distinguishing AAD from ACS. Moreover, the amount of postoperative circulating YAP is a robust indicator of postoperative MAEs.
Related Concept Videos
Aortic Regurgitation II: Clinical Features and Diagnostic Tests
Aortic Regurgitation III: Medical Management
Myocarditis II: Clinical Features and Diagnostic Tests
Acute Coronary Syndrome III: Diagnostic Studies
Dysrhythmias V: Evaluating Dysrhythmias
Aneurysm II: Clinical Manifestations and Diagnostic Studies