Estimation of Central Aortic Pressure Waveforms by Combination of a Meta-Learning Neural Network and a Physics-Driven
Hao Sun1, Junling Ma1, Bao Li1
1College of Chemistry and Life Science, Beijing University of Technology, Beijing, China.
Abstract:
The accurate non-invasive detection and estimation of central aortic pressure waveforms (CAPW) are crucial for reliable treatments of cardiovascular system diseases. But the accuracy and practicality of current estimation methods need to be improved. Our study combines a meta-learning neural network and a physics-driven method to accurately estimate CAPW based on personalized physiological indicators. We collected data from 260 patients who underwent catheterization surgery, using measured CAPW and personalized physiological indicators (e.g., weight, body mass index (BMI), radial mean arterial pressure (MAP), heart rate (HR), cardiac output (CO), radial systolic blood pressure (SBP), and radial diastolic blood pressure (DBP)) as input for neural network training. The output of the neural network are the Gaussian characteristic parameters of the single-period decomposed CAPW. The neural network model was constructed using the model-agnostic meta-learning (MAML) algorithm framework. Applying the physical characteristics of CAPW to the loss function, served to increase the constraints on the output and improve the accuracy of CAPW estimation. To verify the accuracy of the model, we compared measured and estimated CAPW in 52 patients. The results are consistent with a normalized root mean square error (NRMSE) of 0.0206. The predictions had low biases, namely SBP: 4.97 ± 4.42 mmHg, DBP: 4.78 ± 5.98 mmHg, and MAP: 0.35 ± 3.36 mmHg. The results demonstrate the accuracy and practicability of the approach to estimate CAPW. It can provide personalized parameters to calculate myocardial ischemia indicators (e.g., instantaneous wave-free ratio [iFR] and fractional flow reserve [FFR]) and may contribute to the early monitoring and prevention of cardiovascular diseases.
More Related Videos
06:04Author Spotlight: Assessing the Cardiovascular Profile of Patients with Metabolic Syndrome
Published on: September 27, 2024
06:18Intravascular Ultrasound Image-Based Finite Element Modeling Approach for Quantifying In Vivo Mechanical Properties of Human Coronary Artery
Published on: December 6, 2024
Related Concept Videos
Neural Regulation of Blood Pressure
Baroreceptor Reflex
Baroreceptors, located in the carotid sinuses and aortic arch, detect changes in blood pressure. When blood pressure rises, these stretch-sensitive receptors...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Pre-Procedural Guidelines for Assessing Blood Pressure
Assessment of blood pressure in brachial artery(two-step method)