Predicting the Impact of Polysulfone Dialyzers and Binder Dialysate Flow Rate on Bilirubin Removal
Alexander Novokhodko1, Nanye Du1, Shaohang Hao1
1Mechanical Engineering, University of Washington (Seattle), 3900 E Stevens Way NE, Seattle, WA 98195-0001, USA.
Abstract:
Liver failure is the 12th leading cause of death worldwide. Protein-bound toxins such as bilirubin are responsible for many complications of the disease. Binder dialysis systems use albumin or another binding molecule in dialysate and detoxifying sorbent columns to remove these toxins. Systems like the molecular adsorbent recirculating system and BioLogic-DT have existed since the 1990s, but survival benefits in randomized controlled trials have not been consistent. New binder dialysis systems, including open albumin dialysis and the Advanced Multi-Organ Replacement system, are being developed. Optimal conditions for binder dialysis have not been established. We developed and validated a computational model of bound solute dialysis. It predicted the impact of changing between two test setups using different polysulfone dialyzers (F3 and F6HPS). We then predicted the impact of varying the dialysate flow rate on toxin removal. We found that bilirubin removal declines with dialysate flow rate. This can be explained through a linear decline in free bilirubin membrane permeability. Our model quantifies this decline through a single parameter (polysulfone dialyzers). Validation for additional dialyzers and flow rates will be needed. This model will benefit clinical trials by predicting optimal dialyzer and flow rate conditions. Accounting for toxin adsorption onto the dialyzer membrane may improve results further.
More Related Videos
07:11Surgical Techniques for Catheter Placement and 5/6 Nephrectomy in Murine Models of Peritoneal Dialysis
Published on: July 19, 2018
10:19Three-Dimensionally Printed Microfluidic Cross-flow System for Ultrafiltration/Nanofiltration Membrane Performance Testing
Published on: February 13, 2016
Related Concept Videos
Dialysis
Renal Drug Excretion: Effect of Urine pH, Flow Rate, and Drug pKa
The pKa of a...
Renal Drug Excretion: Tubular Secretion
Factors Affecting Renal Clearance: Drug's Physicochemical Properties and Plasma Levels
One important factor is the drug's molecular size. The kidneys readily excrete smaller molecules below 300 Daltons (Da). On the other hand, molecules weighing between 300 and 500 Da are excreted through both urine and bile. Larger molecules above 500 Da tend to be excreted...
Drug Elimination by Renal Route: Tubular Secretion
Hepatic Drug Excretion: Influencing Factors