Signal Processing Workflow for Suspect Screening in LC × LC-HRMS: Efficient Extraction of Pure Mass Spectra for
Paul-Albert Schneide1,2, Oskar Munk Kronik3
1Department of Food Science, University of Copenhagen, 1958 Frederiksberg, Denmark.
Abstract:
The data processing workflows for comprehensive two-dimensional liquid chromatography (LC × LC) hyphenated to high-resolution mass spectrometry (HRMS) operated in data-independent acquisition (DIA) are limited compared to their one-dimensional counterparts. A two-step workflow is proposed to extract pure mass spectra from LC × LC-HRMS. First, a mass filtering (MF) algorithm groups ions belonging to the same compound based on their elution profile similarity in the first (1D) and second dimension (2D). Second, the filtered data are deconvoluted using multivariate curve resolution (MCR) to address potential coelution. The presented workflow is termed MF + MCR and was tested on pulsed elution-LC × LC-HRMS data from a wastewater effluent extract. The proposed workflow was benchmarked to the following three data processing strategies for mass spectra extraction: peak apex (PAM), using the MF approach alone, or using MCR without prior MF. The MF + MCR workflow identified 25 suspect compounds, compared to 23, 16, and 10 identified by MF, MCR, and PAM, respectively. The nine suspects that could not be identified using MCR compared to the MF + MCR all had low total signal contributions, i.e., low intensities compared to the TIC. This showed that adequate preprocessing prior to MCR is essential for trace level analysis. Additionally, it was shown that the MF + MCR workflow extracted statistically significantly purer mass spectra compared to PAM (p-value: 0.003) and MCR (p-value: 0.04) from a spiked blank sample. The results highlight that by utilizing the elution profiles in both chromatographic dimensions, clean mass spectra of analytes at trace levels measured in DIA can be extracted, allowing for more reliable compound identification compared to the workflows that were used for benchmarking.
More Related Videos
14:42Liquid Chromatography Coupled to Refractive Index or Mass Spectrometric Detection for Metabolite Profiling in Lysate-based Cell-free Systems
Published on: September 23, 2021
07:34Large Scale Non-targeted Metabolomic Profiling of Serum by Ultra Performance Liquid Chromatography-Mass Spectrometry UPLC-MS
Published on: March 14, 2013
Related Concept Videos
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
High-Resolution Mass Spectrometry (HRMS)
Mass Spectrometers
Mass Spectrometry: Overview
Peptide Identification Using Tandem Mass Spectrometry
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...
Mass Analyzers: Overview