Related Experiment Video
Updated: Jun 23, 2026

Reduction in Left Ventricular Wall Stress and Improvement in Function in Failing Hearts using Algisyl-LVR
Published on: April 8, 2013
RM Pressfit vitamys: the 10-year follow-up
Pascal C Haefeli1, Zinedine M Zwahlen1, Ralf Baumgärtner1
1Department of Orthopaedic and Trauma Surgery, Lucerne Cantonal Hospital, Spitalstrasse, Lucerne, Switzerland.
The RM Pressfit vitamys hip cup shows excellent 10-year clinical and radiographic outcomes, with a low revision rate of 2.0%. This uncemented, titanium-coated cup demonstrates promising long-term performance in total hip replacements.
Area of Science:
- Orthopedic Surgery
- Biomaterials Science
- Medical Device Technology
Background:
- The RM Pressfit vitamys is an uncemented, titanium particle-coated, isoelastic monoblock cup.
- It is constructed from vitamin E blended highly cross-linked polyethylene.
- This study evaluates its 10-year clinical and radiographic outcomes and revision rate.
Purpose of the Study:
- To assess the 10-year clinical outcomes of the RM Pressfit vitamys hip cup.
- To evaluate the 10-year radiographic results following implantation.
- To determine the cumulative revision rate at the 10-year mark.
Main Methods:
- A prospective observational study involving 162 total hip replacements using the RM Pressfit vitamys cup.
- Data collected at 6 weeks, 1, 5, and 10 years included modified Harris Hip Score (mHHS), pain, satisfaction, and radiographic evaluation.
- Revision rates and complications were systematically recorded.
Main Results:
- At 10 years, 99 hips were evaluated with a mean mHHS of 94.8, minimal pain (0.2 rest, 0.5 load), and high satisfaction (9.5/10).
- Radiographic assessment revealed no cup loosening, acetabular lucent lines, or osteolysis.
- The 10-year cumulative revision rate was 2.0%, with aseptic loosening showing 100% implant survival.
Conclusions:
- The RM Pressfit vitamys cup demonstrates promising 10-year results.
- Good clinical outcomes, including high patient satisfaction and function, were observed.
- Low revision rates and excellent radiographic findings indicate favorable long-term performance.
More Related Videos
09:40Phosphorus-31 Magnetic Resonance Spectroscopy: A Tool for Measuring In Vivo Mitochondrial Oxidative Phosphorylation Capacity in Human Skeletal Muscle
Published on: January 19, 2017
12:59Improving Strength, Power, Muscle Aerobic Capacity, and Glucose Tolerance through Short-term Progressive Strength Training Among Elderly People
Published on: July 5, 2017
Related Concept Videos
Liver Regeneration
Cells of Liver
The liver comprises four major types of cells— hepatocytes, stellate, Kupffer, and sinusoidal endothelial cells. The hepatocytes are large...
Dosage Regimen: Fixed Dose
Fixed-dose regimens can be used for various routes of administration, including intravenous (IV) injections and oral medications. For IV administration, a predetermined amount of the drug is...
Vitamins
Mineral, Vitamin and Water Absorption
Probiotics
Diabetic Retinopathy