Related Experiment Video
Updated: Jun 3, 2025

Modeling Colitis-Associated Cancer with Azoxymethane AOM and Dextran Sulfate Sodium DSS
Published on: September 11, 2012
Relationship Between Adenoma Detection Rate and Respective Withdrawal Time in Different Colon Segments: A
Xujin Chen1, Bingxin Xu1, Bingni Wei1
1Department of Gastroenterology The Affiliated Wuxi People's Hospital of Nanjing Medical University, Wuxi People's Hospital, Wuxi Medical Center, Nanjing Medical University Wuxi Jiangsu China.
Background And Aims:
The 6-min withdrawal time for colonoscopy is widely considered the standard of care. However, there may not be appropriate if the 6-min is equally divided into various colon segments. Since the adenoma detection in each colon segment is not the same, there may be differences with the withdrawal time in different colon segments. Our objective was to evaluate the relationships between adenoma detection rate (ADR) and respective withdrawal time in different colon segments.
Methods:
Outpatients, age range 18-75 years, undertaking complete colonoscopy were enrolled in this study from November 2019 to November 2020 in the digestive endoscopy center. The entire colon was divided into four different segments: ascending colon, transverse colon, descending colon and rectosigmoid colon. The respective withdrawal time and ADR in each colon segment were recorded respectively.
Results:
A total of 586 outpatients (279 males, 307 females) enrolled in this study and the general ADR was 38.2%. The positive withdrawal time (adenomas detected) was longer than negative withdrawal time (non-adenomas detected) (334.04 ± 24.21 s vs. 303.65 ± 5.20 s, t = 1.26, p < 0.001). ADR in ascending colon, transverse colon, descending colon and rectosigmoid colon were respectively 30.5%, 2.9%, 3.1% and 7.5%. While all of their positive withdrawal time were longer than negative withdrawal time (94.34 ± 33.76 s vs. 70.40 ± 41.84 s, t = 3.31, p = 0.001; 85.40 ± 49.76 s vs. 71.66 ± 36.87 s, t = 1.95, p = 0.025; 80.29 ± 39.85 s vs. 69.73 ± 35.96 s, t = 1.40, p = 0.016;100.95 ± 55.92 s vs. 80.96 ± 42.87 s, t = 3.61; p < 0.001, respectively). The withdrawal time threshold in the ascending colon, transverse colon, descending colon, rectosigmoid colon determined by receiver operating characteristic (ROC) curve were 77, 61, 56 and 109 s, respectively. In the ascending colon, ADR was significantly higher (47.0% vs. 33.1%, p < 0.001) when the colonoscopy withdrawal time was ≥ 77 s. When the withdrawal time was ≥ 61 s in the transverse colon (42.7% vs. 32.7%, p = 0.013), ≥ 59 s in the descending colon (42.3% vs. 29.9%, p = 0.004) and ≥ 109 s in rectosigmoid colon (52.2% vs. 33.9%, p < 0.001), ADR was also significantly higher. After adjusting for age, sex and BMI, Logistic regression analysis showed that withdrawal time ≥ 77 s in the ascending colon (OR, 1.796; 95% CI, 1.273-2.532; p < 0.001), ≥ 61 s in the transverse colon (OR, 1.535; 95% CI, 1.094-2.155; p = 0.013), ≥ 56 s in the descending colon (OR, 1.722; 95% CI, 1.193-2.486; p = 0.004) and ≥ 109 s in the rectosigmoid colon (OR, 2.134; 95% CI, 1.446-2.350; p < 0.001) were independent risk factors for the increase of ADR.
Conclusions:
ADR and withdrawal time are all various in individual colon segments. During the operation of colonoscopy, withdrawal time in the ascending colon may be shortened appropriately. The adenomas in the rectosigmoid colon are more likely to be detected and do not take longer withdrawal times. We need to choose the appropriate time according to different colon segments.
More Related Videos
08:26Clinical Application of Single-Surgeon, Three-Port, Laparoscopic Resection for Colorectal Cancer with Natural Orifice Specimen Extraction
Published on: March 24, 2023
10:31Intraoperative Gastroscopy for Tumor Localization in Laparoscopic Surgery for Gastric Adenocarcinoma
Published on: August 9, 2016