Oxygen Targets for Mechanically Ventilated Adults with Sepsis: Secondary Analysis of the PILOT Trial
Jack C Shapiro1, Jonathan D Casey2, Edward T Qian2
1Vanderbilt University School of Medicine, Vanderbilt University Medical Center, Nashville, TN, USA.
Abstract:
Background: Patients with sepsis frequently require invasive mechanical ventilation. How oxygenation during mechanical ventilation affects clinical outcomes for patients with sepsis remains uncertain. Research Question: To evaluate the effects of different oxygen saturation targets on clinical outcomes for patients with sepsis receiving mechanical ventilation. Study Design and Methods: We performed a secondary analysis of the Pragmatic Investigation of optimaL Oxygen Targets (PILOT) trial dataset among patients who met criteria for sepsis by the Sepsis-3 definition at the time of enrollment. We compared patients randomized to a lower oxygen saturation target (90%; range, 88-92%), an intermediate target (94%; range, 92-96%), and a higher target (98%; range, 96-100%) with regard to the outcomes of 28-day in-hospital mortality and ventilator-free days to study day 28. Results: Of 2541 patients in the PILOT dataset, 805 patients with sepsis were included in the current analysis. In-hospital mortality by day 28 did not differ significantly between the lower target group (48%; 95% confidence interval [CI], 42% to 54%), the intermediate target group (50%; 95% CI, 43% to 56%), and the higher target group (51%; 95% CI, 45% to 56%) (P = 0.83). The number of ventilator-free days to day 28 did not significantly differ between the trial groups, with a mean of 9.9 (standard deviation [SD], 11.8) in the lower oxygen saturation target group, 9.5 (SD, 11.2) in the intermediate group, and 9.4 (SD, 11.4) in the higher group (P = 0.65). Interpretation: Among mechanically ventilated patients with sepsis in a large, randomized trial, the incidence of 28-day in-hospital mortality was not statistically significantly different between the use of a lower, intermediate, or higher oxygen target. However, the confidence intervals included treatment effects that would be clinically meaningfully and further randomized trials of oxygen targets in sepsis are required. Referenced trial name Pragmatic Investigation of optimaL Oxygen Targets Trial (PILOT) ClinicalTrials.gov number NCT03537937URL: https://clinicaltrials.gov/study/NCT03537937.
Related Concept Videos
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Treatment for Pulmonary Arterial Hypertension: Oxygen Therapy for Respiratory Failure
Oxygen therapy is vital in increasing and maintaining blood oxygen levels in PAH patients. As a result, it aids in reducing fatigue,...
Acute Respiratory Failure-V
Ensure that patients are monitored continuously for their response to therapy, including changes in...
Administering Oxygen by Mask
Administering oxygen by mask is a common nursing intervention that provides supplemental oxygen to patients with respiratory distress or chronic lung conditions. This procedure involves delivering oxygen at a specified rate through a face mask connected to an oxygen source.
Equipment
The equipment necessary for this procedure includes:
Mechanical Ventilation I: Indication and Settings
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...


