Evaluation of external and radiological landmark methods for optimizing ultrasound-guided right internal jugular
Artid Samerchua1, Panuwat Lapisatepun2, Pattaranee Srichairatanakool1
1Department of Anesthesiology, Faculty of Medicine, Chiang Mai University, 110 Intavaroros Rd, Muang, Chiang Mai, 50200, Thailand.
Abstract:
The formula-based estimation of the right internal jugular venous (IJV) catheterization depth can be inaccurate when using ultrasound guidance. External landmark-based and radiological landmark-based methods have been proposed as alternatives to estimate the insertion depth. This study aimed to evaluate these methods using transesophageal echocardiography (TEE)-guided insertion depth as the reference. Ninety-seven adult cardiac surgery patients underwent real-time ultrasound-guided right IJV catheterization, with placement at the superior vena cava-right atrium (SVC-RA) junction under TEE guidance. The primary outcome compared the accuracy of external-landmark and radiological-landmark methods in estimating optimal catheter position (2 cm above to 1 cm below the SVC-RA junction), while secondary outcomes assessed their reliability and agreement with TEE. The external-landmark method proved more accurate than the radiological-landmark method (91.8% vs. 68%, p < 0.001) and had a higher correlation with TEE (r = 0.83 vs. 0.67). Bland-Altman analysis showed a mean difference of 0.08 cm between external-landmark and TEE methods (limits of agreement: -1.75 to 1.90 cm) and 0.43 cm for radiological-landmark (limits of agreement: -2.63 to 3.49 cm). Overall, the external-landmark method is a reliable and simple technique for estimating right IJV catheter depth and is more useful in cardiac surgery compared to the radiological-landmark method.Trial registration Thai Clinical Trials Registry (TCTR20200410012). Date registered April 9, 2020.
Related Concept Videos
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above the...
Cardiac Catheterization I: Pre-Procedure Overview
Cardiac Catheterization II: Right Heart Catheterization
Cardiac Catheterization III: Left Heart Catheterization
Venous Thrombosis II: Clinical Manifestations and Diagnostic Studies
Venous Thrombosis III: Interprofessional Care