Related Experiment Video
Updated: Aug 7, 2026

Monitoring the Wall Mechanics During Stent Deployment in a Vessel
Published on: May 8, 2012
Aneurysm dome and vessel pressure measurements with coiling, stent assisted coiling and flow diversion
Timothy A Becker1, Kailey L Lewis1, Holly F Berns1
1Mechanical Engineering Department, Northern Arizona University, Flagstaff, AZ, USA.
Background:
Variability in long-term endovascular treatment outcomes for intracranial aneurysms has prompted questions regarding the effects of these treatments on aneurysm hemodynamics. Endovascular techniques disrupt aneurysmal blood flow and shear, but their influence on intra-aneurysmal pressure remains unclear. A better understanding of aneurysm pressure effects may aid in predicting outcomes and guiding treatment decisions.
Methods:
Medium and large aneurysm models with intramural pressure taps on the dome and parent artery were designed and 3D-printed with vessel-like physical properties from UV-cured materials. The models were connected to a comprehensive flow system consisting of a pulsatile pump and a viscosity-matched blood analog. The system provided physiological pressure and flow control. Real-time pressures were recorded in the aneurysm dome and parent artery during initial placement of coils, stents, flow diverters, and temporary balloons under simulated surgical conditions. Coiling, stent-assisted coiling, and flow diverter placement were performed in both aneurysm sizes. Temporary balloon placement was performed in a large aneurysm model.
Results:
Coiling resulted in 24-30% packing density and diminished intra-aneurysmal flow. Flow diverter placement reduced intra-aneurysmal flow with near complete flow interruption after placement of three consecutive devices across the aneurysm neck. Compared to untreated controls, real-time pressure measurements during coiling and flow diversion showed minimal changes (< 5%) in intra-aneurysmal pressures. Temporary balloon occlusion blocked the parent artery, increasing the pressure proximal to the site of occlusion (by 9%), and reducing the pressure distally (by 14%). This maneuver also dampened intra-aneurysmal pressure to the average distal vessel pressure measurement. Positive control aneurysm models were 3D-printed with a sealed, "healed" neck. These controls verified a sealed neck eliminates intra-aneurysmal pressure.
Conclusion:
Findings quantified minimal changes in intra-aneurysmal pressure during and immediately post-coiling and flow diversion. Intra-aneurysmal flow disruption alone has negligible impact on intra-aneurysmal pressures.
More Related Videos
11:00Experimental Investigation of Secondary Flow Structures Downstream of a Model Type IV Stent Failure in a 180° Curved Artery Test Section
Published on: July 19, 2016
05:41Using a Cell-Tracer Injection to Investigate the Origin of Neointima-Forming Cells in a Rat Saccular Side Wall Model
Published on: March 16, 2022
Related Concept Videos
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessment of blood pressure in brachial artery(two-step method)
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Measurement of Blood Pressure