Related Experiment Video
Updated: Jun 3, 2025

An Ivor Lewis Esophagectomy Designed to Minimize Anastomotic Complications and Optimize Conduit Function
Published on: April 17, 2020
4.5-mm "Ready-Made" Conduit for Primary Chest Closure After Norwood Procedure
Naruhito Watanabe1, Ashley Hapak1, Teimour Nasirov1
1Department of Pediatric Cardiac Surgery, Stanford University, Palo Alto, California.
Abstract:
The Norwood procedure with the right ventricle-to-pulmonary artery (RV-PA) conduit has been the standard procedure for hypoplastic left heart syndrome. However, postoperative management can be challenging related to finding the correct balance between pulmonary and systemic blood flow. One can use hemostatic clips on the RV-PA conduit to temporarily restrict pulmonary blood flow. However, the hemodynamics would become unstable after clip removal. Here we describe a novel technique that allows precise pulmonary blood flow without the addition and removal of clips on the RV-PA conduit, allowing primary chest closure after the Norwood procedure.
Related Concept Videos
Tracheostomy Decannulation
Description of the Procedure
Decannulation refers to the permanent removal of the tracheostomy tube, signaling the resolution of the condition that initially necessitated the tracheostomy. The process requires a well-coordinated interplay between...
Tracheostomy Care I: Pre-procedural Steps
Required Equipment
The equipment necessary for tracheostomy care includes:
Tracheostomy Care II: Procedure
Step 1: Perform hand hygiene, and put on personal protective equipment: gown, gloves, mask...