Related Experiment Video
Updated: Jun 3, 2025

In Vivo Quantification of Hip Arthrokinematics during Dynamic Weight-bearing Activities using Dual Fluoroscopy
Published on: July 2, 2021
Fluoroscopy-guided aspiration of the acutely dislocated total hip arthroplasty: a feasible, high-yield, and safe
Dyan V Flores1,2,3, Abdullah Felemban4, Taryn Hodgdon1,2,3
1Department of Radiology, Radiation Oncology and Medical Physics Faculty of Medicine, University of Ottawa, Ottawa, ON, Canada.
Insights
Fluoroscopic-guided aspiration of acutely dislocated total hip arthroplasty (AD-THA) is a feasible, safe, and high-yield procedure. Targeting the acetabular cup, rather than the femur, yields better results with less fluoroscopy time.
Area of Science:
- Orthopedic Surgery
- Radiology
- Infectious Disease Diagnostics
Background:
- Total hip arthroplasty (THA) dislocation can complicate patient recovery.
- Evaluating for infection in dislocated THA is crucial for appropriate management.
- Synovial fluid aspiration is a key diagnostic tool for THA infection.
Purpose of the Study:
- To assess the feasibility, yield, and safety of fluoroscopic-guided aspiration in acutely dislocated total hip arthroplasty (AD-THA).
- To compare aspiration outcomes based on needle target: acetabular cup versus femur.
Main Methods:
- Retrospective review of 20 fluoroscopic-guided aspirations of AD-THA from January 2005 to December 2023.
- Data collected included aspirate yield, volume, and fluoroscopy time.
- Analysis compared outcomes for acetabular cup versus femoral targeting.
Main Results:
- A high positive yield (95%) was achieved, with 75% spontaneous aspirates.
- Targeting the acetabular cup resulted in significantly higher spontaneous aspiration rates (100% vs. 55%) and larger aspirate volumes (11.2 mL vs. 4.0 mL).
- Acetabular cup targeting also led to shorter fluoroscopy times (32 s vs. 56 s) with no immediate complications.
Conclusions:
- Fluoroscopic-guided aspiration of AD-THA is a safe and effective diagnostic procedure.
- Targeting the acetabular cup is superior, offering higher yield, larger sample volumes, and reduced fluoroscopy exposure.
- Radiologists can confidently perform this technically challenging procedure.
Objective:
To determine the feasibility, yield, and safety of fluoroscopic-guided aspiration of the acutely dislocated total hip arthroplasty (AD-THA).
Materials And Methods:
IRB-approved, retrospective review of fluoroscopic-guided aspirations of AD-THA (January 2005-December 2023) was performed. Data from electronic charts and fluoroscopy images/reports were obtained. Positive yield was defined as spontaneous aspirate or saline rinse adequate for microbiology analysis. Sub-analysis by needle target (acetabular cup or femur) was performed for spontaneous aspiration rate, aspirate volume and fluoroscopy time. Differences between groups were analyzed with unpaired, t-test (2-tail) and between proportions with Fisher's exact test, with significance p < 0.05.
Results:
Aspiration of 20 AD-THA in 19 patients (12 female, mean age (SD) of 73 years (16)) targeted the acetabular cup in 45% (9/20) or femur in 55% (11/20) of cases. Positive yield was obtained in 95% (19/20), with spontaneous aspirate in 75% (15/20) and saline rinse in 20% (4/20) of cases; in 5% (1/20), no diagnostic sample was obtained. Spontaneous aspirate mean volume (SD, range) for all cases was 8.3 mL (6.9, 0.2-25), and higher when targeting the acetabular cup 11.2 mL (6.9, 5-25) versus the femur 4.0 mL (4.4, 0.2-12) (p = 0.026). The rate of spontaneous aspiration was higher for the acetabular cup 100% (9/9) versus the femur 55% (6/11) (p = 0.038). The mean fluoroscopy time (SD, range) for all cases was 43 s (25, 19-102), and shorter for targeting the acetabular cup 32 s (16, 19-75) versus the femur 56 s (28, 28-102) (p = 0.034). No immediate complications occurred in all aspirations.
Conclusion:
Fluoroscopy-guided aspiration of AD-THA is a feasible, high-yield, and safe procedure. Targeting the acetabular cup results in a higher rate of spontaneous aspirate, larger aspiration volume, and lower fluoroscopy time.
Critical Relevance Statement:
Although technically more challenging, radiologists should feel confident aspirating the acutely dislocated total hip arthroplasty (AD-THA) under fluoroscopic guidance.
Key Points:
Total hip arthroplasty (THA) infection can be evaluated with synovial fluid aspiration. Fluoroscopic-guided aspiration of the dislocated THA is feasible, high-yield, and safe. Targeting of the acetabular cup is recommended over the femoral prosthetic component. Acetabular cup targeting gives larger, spontaneous aspirates with lower fluoroscopy time.