Related Experiment Video
Updated: Jun 3, 2025

Author Spotlight: Advancing Awake Nasotracheal Intubation with Flexible Video Rhino-Laryngoscopes
Published on: August 2, 2024
The C-MAC video laryngoscope helps presbyopic anesthetists to overcome difficulty in neonatal and infantile
Ashraf E Abdalla1, Mohsen M Eissa2, Mohamed R Elbasyouny2
1Department of Anesthesia, ICU & Pain, Faculty of Medicine (Boys), Al-Azhar University, Cairo, Egypt. ashrafabdalla702@yahoo.com.
Background:
Endotracheal intubation (ETI) is a life-saving procedure that must be accurately carried on to guard against complications. Presbyopia leads to difficulty in viewing close objects and may obstacle proper intubation even with the best hands.
Purpose:
This study supposed that the use of video-laryngoscope (VL) may provide better intubation conditions for presbyopic anesthetists and targets to evaluate the neonates and infants' intubation success rates (ISR) by anesthetists aged ≥ 45 years using the C-MAC VL compared to the standard laryngoscope (SL).
Methods:
Thirty-one neonates with an age of 18.2 ± 5.2 days and a body weight of 4.5 ± 0.3 kg and 103 infants aged 8.6 ± 1 months and weighing 9.4 ± 1.5 kg were randomly categorized into the SL group that received ETI using the SL and the VL group had intubated using the C-MAC® (Karl Storz, Germany) VL with the standard Miller blade and flexible Stylet (2 mm PORTEX® stylet; Smiths Medical International Ltd., UK) to strengthen the endotracheal tube (ETT) and adjust its curvature as C-shaped. The study outcomes included the frequency of successful intubation and the number of intubation attempts.
Results:
The ISR was significantly (P < 0.001) higher with significantly (P = 0.0037) lower frequency of using assistance maneuvers with VL. The mean score of the anesthetist's difficulty rating was significantly (P < 0.001) higher with SL (2.7 ± 2) than with VL (1.27 ± 1.27). Times for the full intubation process were significantly (P < 0.001) shorter with VL than SL. The 1st attempt success rate was significantly (P = 0.0195) higher with VL than SL (86.6% vs. 67.2%). The frequency of maneuver-related complications was insignificantly (P = 0.116) reduced with the use of VL (4.5%) than with SL (12%). The ISR showed a negative significant correlation (r=-0.973, P = 0.005) with the anesthetist's age.
Conclusion:
Neonatal and infantile intubation using VL is feasible and easy to handle by aged anesthetists and allows higher ISR and 1st attempt rate with minimal need for external assistant maneuvers and maneuver-related complications. VL might be more appropriate for the presbyopic pediatric anesthetists than the SL.
Limitations:
The limitations of the study are the small sample size of anesthetists and the use of one type of VLs.
Related Concept Videos
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...
Tracheostomy Care I: Pre-procedural Steps
Required Equipment
The equipment necessary for tracheostomy care includes:
Tracheostomy Decannulation
Description of the Procedure
Decannulation refers to the permanent removal of the tracheostomy tube, signaling the resolution of the condition that initially necessitated the tracheostomy. The process requires a well-coordinated interplay between...
Endotracheal Intubation II: Nursing Management
1. Nursing Care of Patients Before Intubation
Before the endotracheal intubation procedure, nurses play an essential role in ensuring the process goes smoothly. The nurses must be familiar with intubation...