Related Experiment Video
Updated: Jun 3, 2025

Fruit Volatile Analysis Using an Electronic Nose
Published on: March 30, 2012
Electrochemical Fingerprint Analyses Using Voltammetry and Liquid Chromatography Coupled with Multivariate Analyses
Koichi Machida1, Akira Kotani1, Tomoya Osaki1
1Department of Analytical Chemistry, School of Pharmacy, Tokyo University of Pharmacy and Life Sciences, Hachioji 192-0392, Japan.
Abstract:
The appearances of Schisandrae Sphenantherae Fructus (SSF) and Schisandrae Chinensis Fructus (SCF) are very similar. Thus, being able to distinguish between SSF and SCF is useful for the quality control of these herbal medicines. In this study, two kinds of electrochemical fingerprint analyses using voltammetry or HPLC with electrochemical detection (HPLC-ECD) were developed in combination with multivariate analysis for discriminating between SSF and SCF. The data sets of the oxidation current values from voltammograms of SSF and SCF samples ranging from +0.5 to +1.0 V were applied to perform a partial least squares discriminant analysis (PLS-DA). Moreover, the data sets of the current heights of the characteristic target peaks on the chromatograms at an applied potential of +0.9 V were also applied to perform PLS-DA. In each PLS-DA obtained from the voltammograms and chromatograms, the scores for the SSF samples were plotted on a different region compared with the scores for the SCF samples. Considering the results of the cross-validation, the HPLC-ECD clearly discriminated between the SSF and SCF samples when compared with the voltammetry. In conclusion, our results show that the present electrochemical fingerprint analyses coupled with PLS-DA are useful as a means for discriminating between the SSF and SCF samples.
More Related Videos
07:29HPLC Coupled with Chemical Fingerprinting for Multi-Pattern Recognition for Identifying the Authenticity of Clematidis Armandii Caulis
Published on: November 11, 2022
11:14Rapid High-throughput Species Identification of Botanical Material Using Direct Analysis in Real Time High Resolution Mass Spectrometry
Published on: October 2, 2016
Related Concept Videos
High-Performance Liquid Chromatography: Types of Detectors
Voltammetric Techniques: Linear-Scan (E vs Time)
Voltammetry: Stripping Methods
Anodic Stripping Voltammetry (ASV)
ASV is used to determine metals and metalloids at trace levels. It involves two steps: deposition and stripping. First, a negative potential is applied to the...
Capillary Electrophoresis: Instrumentation
Electrogravimetric Analysis: Overview
To test the completeness of the...
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...