Related Experiment Video
Updated: Jun 3, 2025

Continuous-Wave Propagation Channel-Sounding Measurement System - Testing, Verification, and Measurements
Published on: June 25, 2021
Application of PN Code in Time Delay Measurement of Telephone Network
Xiaozhen Jin1,2, Yu Hua1,2
1National Time Service Center, Chinese Academy of Sciences, Xi'an 710600, China.
Abstract:
Telephone time service is a wired time service that transmits time signals through a telephone network, with the advantages of simple receiving equipment and wide coverage. But the performance of time service is not high, usually several milliseconds. The time delay measurement of the telephone network is an important factor limiting the improvement in timing performance. The existing telephone service systems measure time delay based on sending characters. The time fluctuation of modulating and demodulating characters and the low accuracy of detecting characters affect the uncertainty of time delay measurement. This article proposes a time delay measurement method based on sending PN codes. It utilizes the good autocorrelation properties of PN codes to improve detection accuracy and then improve the uncertainty of delay measurement. This article studies and designs the modulation, demodulation, and capture of PN codes. Simulation has verified that this method has strong anti-noise performance. Time delay tests have proved that this method can improve the uncertainty of delay measurement by an order of magnitude in different telephone network environments.
More Related Videos
07:49Automated Deployment of an Internet Protocol Telephony Service on Unmanned Aerial Vehicles Using Network Functions Virtualization
Published on: November 26, 2019
00:07A Photonic System for Generating Unconditional Polarization-Entangled Photons Based on Multiple Quantum Interference
Published on: September 5, 2019
Related Concept Videos
Design Example
Pilot and Numeric Relaying
Time and frequency -Domain Interpretation of Phase-lead Control
The design of phase-lead control involves the strategic placement of poles and zeros to balance steady-state error and system...
Sampling Continuous Time Signal
In the...
Line Protection with Impedance Relays
Under normal conditions, low load currents keep the measured...
Boundary Conditions: Lossless Lines