Related Experiment Video
Updated: Dec 9, 2025

In Situ Soil Moisture Sensors in Undisturbed Soils
Published on: November 18, 2022
Monitoring Excavation-Induced Deformation of a Secant Pile Wall Using Distributed Fiber Optic Sensors
Chengyu Hong1,2, Chengkai Xu3, Weibin Chen2
1China Railway Seventh Group Co., Ltd., Zhengzhou 450016, China.
Abstract:
This paper investigates the use of the BOTDA (Brillouin Optical Time-Domain Analysis) technology to monitor a large-scale bored pile wall in the field. Distributed fiber optic sensors (DFOSs) were deployed to measure internal temperature and strain changes during cement grouting, hardening, and excavation-induced deformation of a secant pile wall. The study details the geological conditions and DFOS installation process. During grouting, the temperature increased by approximately 69 °C due to cement hydration 30 min post-grouting, while the strain decreased by 0.5% on average due to cement slurry shrinkage. During excavation, the temperature changes were minimal, but the excavation depth significantly influenced the strain distribution, with continuous compressive deformation observed in two monitored boreholes. Two analytical methods, the numerical integration method (NIM) and the finite difference method (FDM), were used to calculate the lateral pile displacement based on the monitored strain data. The results were compared with previous monitoring data, showing that the lateral displacement of the pile was minimal after excavation and was attributed to the high stiffness of the secant pile wall. This study demonstrates the effectiveness of DFOSs and BOTDA technology for monitoring complex pile wall behaviors during construction.
Related Concept Videos
Posttensioned Masonry Walls
Post-tensioned masonry walls use high-strength steel rods or flexible tendons to enhance the strength and efficiency of masonry structures. These elements are securely anchored to the foundation and extend vertically either within the cores of the masonry units or between the masonry wythes. The construction process involves building the wall with these tensioning elements in place and allowing the mortar to fully cure.
Following the curing process, the tensioning begins. Steel rods are...
Fiber Reinforced Concrete
Dynamic Modulus of Elasticity of Concrete
The sonic test is a common method to determine the dynamic modulus. In this test, a concrete beam, sized either 6 x 6 x 30 inches or 4 x 4 x 20 inches, is clamped at its center. Vibrations are initiated at one end of the beam by an electromagnetic exciter unit powered by a...