Spectral Content Effects Study in Non-Contact Resonance Ultrasound Spectroscopy
Muhammad Tayyib1, Linas Svilainis1
1Department of Electronics Engineering, Kaunas University of Technology, 51368 Kaunas, Lithuania.
Abstract:
The application of spread-spectrum signals (arbitrary pulse width and position (APWP) sequences) in air-coupled resonant ultrasound spectroscopy is studied. It was hypothesized that spread-spectrum signal optimization should be based on te signal to noise ratio (SNR). Six APWP signal optimization criteria were proposed for this purpose. Experimental measurements were conducted using a thin polycarbonate sample using two standard spread-spectrum signals, linear and nonlinear frequency modulation, together with six optimized APWP signals. It was found that the performance of APWP signals derived from linear frequency modulation was better. The two best performing optimization criteria are SNR improvement on a linear scale with the SNR as an additional weight and energy improvement on a dB scale. The influence of spectral coverage on measurement errors was evaluated. It was found that it is sufficient to cover the sample resonance peak and the valley. The lowest error rates for density, 3%, and for thickness, 3.5%, were achieved when the upper valley was covered. For velocity, the best result, 5%, was achieved when the lower valley was covered. The lowest error rate for attenuation, 3.8%, was achieved in the case when both valleys were covered. Yet no significant performance degradation was noted when a whole -30 dB passband was covered.
Related Concept Videos
IR Spectroscopy: Molecular Vibration Overview
Stretching vibrations are vibrational motions that occur along the bond line, changing the bond length or distance between two bonded atoms. They are further distinguished as symmetric or asymmetric. In symmetric stretching, the...
Raman Spectroscopy: Overview
However, a small fraction of the scattered light exhibits a frequency shift due to the exchange of energy between the incident photons and...
Sound Waves: Resonance
IR Spectrum Peak Splitting: Symmetric vs Asymmetric Vibrations
Spectrophotometry: Introduction
The essential components of a spectrophotometer include a source of electromagnetic radiation, a slot for placing a material to be analyzed, and a...
UV–Vis Spectroscopy: Woodward–Fieser Rules