Double-Helix Electrode Ion Funnel: A New Ion Funnel Design with an Extended Mass Range
Bin Wu1, Xingliang He1, Xing Guo1
1Research Center of Analytical Instrumentation, School of Mechanical Engineering, Sichuan University, Chengdu 610065, People's Republic of China.
Abstract:
The development of an atmospheric pressure interface (API) with a high ion transfer efficiency and wide mass range is advantageous for the performance improvement of mass spectrometry (MS) instruments. In this work, a novel ion guide, namely, the double-helix electrode ion funnel (DHE-IF), has been developed to enhance the ion transmission over a wide mass range in the rough vacuum region. The DHE-IF consists of two funnel-shaped helix electrodes. There are almost no potential "traps" along the central axis of DHE-IF due to the continuous double-helix electrode structure compared to the stacked ring ion funnel. The electrode design of the DHE-IF assembly was guided by ion trajectory simulations. After being fabricated, DHE-IF was integrated into an ESI-TOF-MS platform for tests. A conventional stacked ring ion funnel (IF) was also tested for comparison. The experimental results showed that DHE-IF extended the transmission window of the IF and improved the efficiency of the simultaneous transferring of low and medium m/z ions. In addition, the intensities of caffeine ions (m/z = 195) and reserpine ions (m/z = 609) were enhanced by more than 50% and 10%, respectively. These values were compared with the results obtained by the IF. The DHE-IF is expected to be widely used as an ion import device in MS instruments, which is due to its improved performance and advantages in, e.g., integration and power supply design.
More Related Videos
Related Concept Videos
Mass Analyzers: Common Types
Mass Analyzers: Overview
Electrospray Ionization (ESI) Mass Spectrometry
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
Mass Spectrometers
Tandem Mass Spectrometry
Secondary fragmentations occur in the interaction cell and can be induced by various factors. Fragmentation induced by collision with inert gases, such as N2, Ar, He, etc., is called collision-induced...
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...