Related Experiment Video
Updated: Jun 3, 2025

Preparation of Polyoxometalate-based Photo-responsive Membranes for the Photo-activation of Manganese Oxide Catalysts
Published on: August 7, 2018
Preliminary mechanistic insights into the detection of ethanol vapour using MnO2 NRs-CNPs-poly-4-(vinylpyridine)
Lesego Malepe1, Derek Tantoh Ndinteh1, Patrick Ndungu2
1Department of Chemical Sciences, University of Johannesburg, PO Box 17011, Doornfontein, 2028, Johannesburg, South Africa.
Abstract:
Semiconductor metal oxide gas sensors are widely used to detect ethanol vapours, commonly used in industrial productions, road safety detection, and solvent production; however, they operate at extremely high temperatures. In this work, we present manganese dioxide nanorods (MnO2 NRs) prepared via hydrothermal synthetic route, carbon soot (CNPs) prepared via pyrolysis of lighthouse candle, and poly-4-vinylpyridine (P4VP) composite for the detection of ethanol vapour at room temperature. MnO2, CNPs, P4VP, and MnO2 NRs-CNPs-P4VP composite were characterised using scanning electron microscopy, transmission electron microscopy, powder X-ray diffraction, Fourier transform infrared spectroscopy, and Raman spectroscopy. Five sensors were prepared, namely, sensor 1 (MnO2 -NRs), sensor 2 (CNPs), sensor 3 (CNPs-P4VP composite of a mass ratio of 1:3), sensor 4 (MnO2 NRs-CNPs-P4VP composite of a mass ratio 1:1:3), and sensor 5 (MnO2 NRs-CNPs-P4VP composite of a mass ratio 2:1:3). All the five sensors were used detect to 2-propanol, acetone, ethanol, methanol, and mesitylene vapours at room temperature, but among all the tested sensors, sensor 4 was highly sensitive to ethanol vapour and less sensitive to 2-propanol, methanol, acetone, and mesitylene vapours. The response and recovery time of sensor 4 towards ethanol vapour at 20.4 ppm were 82 seconds and 74 seconds, respectively. The limit of detection on ethanol vapour using sensor 4 was 789 ppb. During detection, the ethanol vapour undergoes total deep oxidation on the surface of sensor 4.
Related Concept Videos
¹H NMR of Labile Protons: Temporal Resolution
The –OH proton in alcohols typically appears in the range of δ 2 to 5 ppm but can vary depending on the specific...
IR and UV–Vis Spectroscopy of Aldehydes and Ketones
IR Spectroscopy: Molecular Vibration Overview
Stretching vibrations are vibrational motions that occur along the bond line, changing the bond length or distance between two bonded atoms. They are further distinguished as symmetric or asymmetric. In symmetric stretching, the...
UV–Vis Spectroscopy: Molecular Electronic Transitions

