Iris retractor-assisted optic capture of a 3-piece intraocular lens
Jordan Philip Safran1, Steven Safran2
1Sidney Kimmel Medical College, Thomas Jefferson University, Philadelphia, PA, USA.
Abstract:
Optic capture of a three-piece lens in the absence of posterior capsule support is an effective strategy for stabilizing and sequestering the optic to reduce the risk of dislocation and UGH syndrome compared to sulcus placement. We present a novel technique that facilitates optic capture in the presence of a contracted, fibrotic rhexis opening, while minimizing stress on the zonules by using iris retractors to assist in stabilization and expansion of the rhexis, followed by direct injection of the optic of the lens behind the anterior capsule opening into an optic captured configuration.