Estimating whole-body centre of mass sway during quiet standing with inertial measurement units
Liam H Foulger1, Emma R Reiter1, Calvin Kuo2,3
1School of Kinesiology, University of British Columbia, Vancouver, British Columbia, Canada.
Abstract:
Our ability to balance upright provides a stable platform to perform daily activities. Balance deficits associated with various clinical conditions may affect activities of daily living, highlighting the importance of quantifying standing balance in ecological environments. Although typically performed in laboratory settings, the growing availability of low-cost inertial measurement units (IMUs) allows the assessment of balance in the real world. However, it is unclear how many IMUs are required to adequately estimate linear displacements of the centre of mass (CoM) at stance widths associated with daily activities. While wearing IMUs on their head, sternum, back, right thigh, right shank, and left shank, 16 participants stood quietly on a force platform in narrow, hip-width, and shoulder-width stances, each for three two-minute trials. Using a multi-segment biomechanical model, we estimated CoM displacements from all possible combinations of the IMUs. We then calculated the correlation between the IMU- and force platform- CoM estimates to determine the minimal number of IMUs needed to estimate CoM sway. Four IMUs were necessary to accurately estimate anteroposterior (AP) and mediolateral (ML) CoM displacements across stance widths. Using IMUs on the back, right thigh, and both shanks, we found strong correlations between the IMU CoM estimation and the force platform CoM estimation in narrow stance (AP: r = 0.92±0.04, RMSE = 2.39±2.08 mm; ML: r = 0.97±0.02, RMSE = 1.16±0.77 mm), hip-width stance (AP: r = 0.93±0.04, RMSE = 2.00±1.18 mm; ML: r = 0.92±0.06, RMSE = 0.92±0.70 mm), and shoulder-width stance (AP: r = 0.93±0.03, RMSE = 1.95±1.66 mm; ML: r = 0.86±0.13, RMSE = 1.39±1.46 mm). These results indicate that IMUs can be used to estimate CoM displacements during quiet standing and that four IMUs are necessary to do so. Using an algorithm based on a simple biomechanical model, researchers and clinicians can estimate whole-body CoM displacements accurately during unperturbed quiet standing. This approach can improve the ecological validity of standing balance research and opens the possibility for assessing/monitoring patients with standing balance deficits.
Related Concept Videos
Center of Mass: Introduction
Center of Mass
The knowledge of the center of mass can also help us to describe and predict the motion of objects. For example, when a ball is thrown...
Equation of Motion: Center of Mass
Internal forces between any pair of particles manifest as collinear pairs of equal magnitude but opposite directions,...
Finding the Center of Gravity
Significance of Center of Mass
Rigid Body Equilibrium Problems - I