Related Experiment Video
Updated: Jun 2, 2025

Experimental Protocol to Determine the Chloride Threshold Value for Corrosion in Samples Taken from Reinforced Concrete Structures
Published on: August 31, 2017
Damage constitutive model and mechanical properties of a concrete limestone composite after acid corrosion
Jie Wang1, Bin Du1, Mingxuan Shen2
1College of Civil Engineering, Guizhou University, Huaxi District, Guiyang, 550025, Guizhou, China.
Abstract:
Long-term erosion by acidic solutions in karst regions leads to continuous deterioration of the physical and mechanical properties at the interfaces of engineering structures, adversely affecting their operational performance. To investigate the degradation patterns of the mechanical properties and corrosion mechanisms of the concrete‒limestone composite (CLC) after exposure to acidic corrosion, three kinds of CLC samples treated with acidic solutions of different pH values were fabricated. Mechanical property analysis was conducted via triaxial compression testing methods. Lemaitre's strain equivalence hypothesis was utilized, and on the basis of the assumption that the strength of rock microelements follows a Weibull distribution, the damage to microelements due to acidic corrosion was combined with compressive failure. The study results indicate that acidic corrosion significantly affects the mechanical properties and failure modes of CLCs. As the pH of the solution decreased from 7 to 5 and then to 3, the peak strengths of the samples decreased by 16.6% and 11.92%, whereas the elastic moduli decreased by 25.36% and 23.13%, respectively. Furthermore, with increasing confining pressure, the peak and residual strengths of the composite significantly improved; the residual strength increased from 8.2 MPa to 86.93 MPa as the confining pressure increased from 0 to 10 MPa. Finally, by introducing a damage constitutive model corrected for postpeak residual strength, the stress‒strain full-process curves of CLCs under different degrees of acidic corrosion were more accurately simulated. The validation results confirm the applicability and accuracy of the established model, providing a theoretical basis and technical support for understanding and predicting the mechanical behavior of limestone-concrete structures in acidic environments.
Related Concept Videos
Acid Attack on Concrete
The rate at which hydrogen...
Corrosion of Reinforcement
However, over time and under certain conditions like carbonation, chloride ingress, and cracking this protective state can be compromised. Steel has areas with...
Effect of Sea Water on Concrete
Concrete in areas between tide marks,...
Sulfate Attack on Concrete
Sulfates from sources like soil, groundwater, or industrial effluents...
Alkali Aggregate Reaction in Concrete
Strength of Cement
For compressive strength tests, ASTM C 109-05 standards prescribe a cement-sand mix ratio of 1:2.75 and a water/cement ratio of 0.485 for making 2-inch cubes. These cubes are mixed, cast, and cured in saturated lime water at 23°C until testing. Flexural strength testing, outlined in...

