Related Experiment Video
Updated: May 1, 2026

Dynamic Lung Tumor Tracking for Stereotactic Ablative Body Radiation Therapy
Published on: June 7, 2015
Radiomics and dosiomics approaches to estimate lung function after stereotactic body radiation therapy in patients
Yoshiro Ieko1,2, Noriyuki Kadoya3, Shohei Tanaka1
1Department of Radiation Oncology, Tohoku University Graduate School of Medicine, 1-1 Seiryo-machi, Aoba-ku, Sendai, 980-8574, Japan.
Abstract:
Lung function assessment is essential for determining the optimal treatment strategy for radiation therapy in patients with lung tumors. This study aimed to develop radiomics and dosiomics approaches to estimate pulmonary function test (PFT) results in post-stereotactic body radiation therapy (SBRT). Sixty-four patients with lung tumors who underwent SBRT were included. Models were created to estimate the PFT results at 0-6 months (Cohort 1) and 6-24 months (Cohort 2) after SBRT. Radiomics and dosiomics features were extracted from the computed tomography (CT) images and dose distributions, respectively. To estimate the PFT results, Models A (dose-volume histogram [DVH] + radiomics features) and B (DVH + radiomics + dosiomics features) were created. In the PFT results, the forced expiratory volume in one second (FEV1) and forced vital capacity (FVC) were estimated using each model, and the ratio of FEV1 to FVC (FEV1/FVC) was calculated. The Pearson's correlation coefficient (Pearson r) and area under the curve (AUC) for FEV1/FVC (< 70%) were calculated. The models were evaluated by comparing them with the conventional calculation formulae (Conventional). The Pearson r (FEV1/FVC) values were 0.30, 0.64, and 0.69 for Conventional and Models A and B (Cohort 2), respectively, and the AUC (FEV1/FVC < 70%) values were 0.63, 0.80, and 0.78, respectively. This study demonstrates the possibility of estimating lung function after SBRT using radiomics and dosiomics features based on planning CT images and dose distributions.
More Related Videos
08:54Treatment of Liver Metastases Using an Internal Target Volume Method for Stereotactic Body Radiotherapy
Published on: May 8, 2018
06:20Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition
Published on: March 11, 2021
Related Concept Videos
Biological Effects of Radiation
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET