A comparison between 64-projection and 32-projection myocardial perfusion scintigraphy
Seyed Mohammad Abedi1, Erfan Ghadirzadeh2, Hanie Karimi3
1Department of Radiology and Nuclear Medicine, Faculty of Medicine, Cardiovascular Research Center, Mazandaran University of Medical Sciences, 4818813371 Sari, Iran.
Aims:
While most clinical guidelines recommend using a 64-projection view technique, some protocols do not specify a preference between 32-projection and 64-projection methods for conducting myocardial perfusion scintigraphy (MPS), which shows the lack of consensus in this matter. Nevertheless, these guidelines and protocols have not provided us with compelling evidence to support why the 64-projection technique is usually chosen. Thus, we aimed to determine if there is a significant difference between them in the assessment of cardiac perfusion and functional indices.
Methods And Results:
Sixty-nine patients were included in this pilot prospective, cross-sectional, cross-over, same patient control protocol study and underwent 32- and 64-projection MPS at both stress and rest phases after injecting 740-925 MBq of 99mTc-MIBI for every patient. Then, cardiac indices, including summed stress, rest, and difference scores, extent-stress and rest, left ventricular volumes and ejection-fraction, peak filling rate (PFR), and time to peak filling rate (TTPF) were recorded. Lin's concordance correlation coefficient was used to assess the agreement between protocols, and a paired sample t-test was used to compare the means of variables where appropriate. Findings revealed no significant difference as well as excellent/good agreement between the two methods in either the stress or rest state, except for the TTPF and PFR.
Conclusion:
The findings suggest that lower-projection techniques could be adequate for routine clinical assessments without sacrificing diagnostic accuracy. However, the poor agreement for PFR and TTPF indicates that the 32-projection method may not reliably assess diastolic function, implying that the 64-projection protocol is preferable when precise evaluations are necessary.
Related Concept Videos
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for...