Nuclear interaction correction based on dual-energy computed tomography in carbon-ion radiotherapy
Yushi Wakisaka1,2, Masashi Yagi3, Yuki Tominaga1,2
1Medical Physics Laboratory, Division of Health Science, Osaka University Graduate School of Medicine, Osaka, Japan.
Abstract:
Objective.Accurate dose predictions are crucial to maximizing the benefits of carbon-ion therapy (CIT). Carbon beams incident on the human body cause nuclear interactions with tissues, resulting in changes in the constituent nuclides and leading to dose errors that are conventionally corrected using conventional single-energy computed tomography (SECT). Dual-energy computed tomography (DECT) has frequently been used for stopping power estimation in particle therapy and is well suited for correcting nuclear reactions because of its detailed body-tissue elemental information. This study proposes a correction method for the absolute dose in CIT that considers changes in nuclide composition resulting from nuclear reactions with body tissues, as a novel application of DECT.Approach.The change in dose associated with nuclear reactions is determined by correcting each integrated depth dose component of the carbon beam using a nuclear interaction correction factor. This factor is determined based on the stopping power, mass density, and nuclear interaction cross-section in body tissue. The stopping power and mass density were calculated using established methods, whereas the nuclear interaction cross-section was newly defined through a conversion equation derived from the effective atomic number.Main results.Nuclear interaction correction factors and corrected doses were determined for 85 body tissues with known compositions, comparing them with existing SECT-based methods. The root-mean-square errors of the SECT- and DECT-based nuclear interaction correction factors relative to theoretical values were 0.66% and 0.39%, respectively.Significance.This indicates a notable enhancement in the estimation accuracy with DECT. The dose calculations in uniform body tissues derived from SECT showed slight over-correction in adipose and bone tissues, whereas those based on DECT were almost consistent with theoretical values. Our proposed method demonstrates the potential of DECT for enhancing dose calculation accuracy in CIT, complementing its established role in stopping power estimation.
More Related Videos
10:24Neutron Radiography and Computed Tomography of Biological Systems at the Oak Ridge National Laboratory's High Flux Isotope Reactor
Published on: May 7, 2021
09:49A Whole Body Dosimetry Protocol for Peptide-Receptor Radionuclide Therapy PRRT: 2D Planar Image and Hybrid 2D+3D SPECT/CT Image Methods
Published on: April 24, 2020
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...