Related Experiment Video
Updated: Jun 1, 2025

A Detailed Protocol for Perspiration Monitoring Using a Novel, Small, Wireless Device
Published on: November 24, 2016
Ultra-Fast Moisture Sensor for Respiratory Cycle Monitoring and Non-Contact Sensing Applications
Suman Mandal1, Harold Mazo Mantilla1, Kalaivanan Loganathan1
1Physical Science and Engineering Division, King Abdullah University of Science and Technology (KAUST), Thuwal, 23955-6900, Saudi Arabia.
Abstract:
As human-machine interface hardware advances, better sensors are required to detect signals from different stimuli. Among numerous technologies, humidity sensors are critical for applications across different sectors, including environmental monitoring, food production, agriculture, and healthcare. Current humidity sensors rely on materials that absorb moisture, which can take some time to equilibrate with the surrounding environment, thus slowing their temporal response and limiting their applications. Here, this challenge is tackled by combining a nanogap electrode (NGE) architecture with chicked egg-derived albumen as the moisture-absorbing component. The sensors offer inexpensive manufacturing, high responsivity, ultra-fast response, and selectivity to humidity within a relative humidity range of 10-70% RH. Specifically, the egg albumen-based sensor showed negligible response to relevant interfering species and remained specific to water moisture with a room-temperature responsivity of 1.15 × 104. The nm-short interelectrode distance (circa 20 nm) of the NGE architecture enables fast temporal response, with rise/fall times of 10/28 ms, respectively, making the devices the fastest humidity sensors reported to date based on a biomaterial. By leveraging these features, non-contact moisture sensing and real-time respiratory cycle monitoring suitable for diagnosing chronic diseases such as sleep apnea, asthma, and pulmonary disease are demonstrated.
Related Concept Videos
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...

