Related Experiment Video
Updated: Jun 1, 2025

Author Spotlight: A Non-Intubated Video-Assisted Thoracoscopic Surgery with Multimodal Analgesia and Sevoflurane Inhalation Anesthesia
Published on: May 26, 2023
Factors related to cough strength before tracheal extubation in post-cardiac surgery patients: A cross-sectional
Yan Zhang1, Zheng Lin2,3, Yuhong Chen4
1Department of Intensive Care Medicine, Nanjing First Hospital, Nanjing Medical University, Nanjing, Jiangsu, China.
Background:
Tracheal extubation failure after cardiac surgery is associated with diminished cough strength, albeit the information on cough strength in post-cardiac surgery patients is limited.
Aim:
To investigate the cough strength in patients after cardiac surgery before tracheal extubation and the related influencing factors.
Study Design:
A cross-sectional study was designed, with adherence to the STROBE guidelines. The participants were 528 patients undergoing open-heart cardiac surgery who were admitted to the Cardio Surgical Centre in a tertiary hospital in Nanjing, China, from August 2022 to September 2023. Cough peak flow (CPF) ≤60 L/min set as the cut-off value for evaluating diminished cough strength before tracheal extubation. Univariate analysis and multiple linear regression analysis were used to analyse the related influencing factors.
Results:
The mean CPF was 130.70 ± 50.58 L/min. A total of 76 (14.4%) patients exhibited a CPF of ≤60 L/min. Multiple linear regression analysis revealed that gender (B = 14.266, t = 2.456, p = .014), inspiratory capacity (IC) (B = 0.013, t = 3.755, p < .001), preoperative CPF (B = 0.086, t = 3.903, p < .001), muscle strength (B = 12.423, t = 4.242, p < .001), preoperative exercise regimen (B = 16.716, t = 4.236, p < .001) and pain levels (B = -8.115, t = -5.794, p < .001) significantly contributed to cough strength.
Conclusions:
Female gender, lower upper limb muscle strength, higher pain levels, lower preoperative CPF and IC, and the absence of systematic exercise were found to be associated with diminished cough strength.
Relevance To Clinical Practice:
Cough strength provides important auxiliary data in extubation decision-making. In addition, understanding its relevant factors can help identify the high-risk group of tracheal extubation failure and can help provide a strong theoretical basis for the development of personalized interventions.
Related Concept Videos
Endotracheal Tube Extubation
Procedure
Extubation removes the endotracheal tube (ETT) from the patient on mechanical ventilation. It requires a well-coordinated, multidisciplinary approach involving physicians, nurses, respiratory therapists, and other healthcare professionals....
Endotracheal Intubation II: Nursing Management
1. Nursing Care of Patients Before Intubation
Before the endotracheal intubation procedure, nurses play an essential role in ensuring the process goes smoothly. The nurses must be familiar with intubation...
Tracheostomy Suctioning I: Pre-Procedural Steps
Equipment Required
First, gather all necessary equipment: a sterile suction catheter, a sterile disposable container, sterile gloves, a towel or...
Tracheostomy Suctioning II: Procedure
Factors Affecting Pulmonary Ventilation
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...