A Basic Positron Emission Tomography System Constructed to Locate a Radioactive Source in a Bi-dimensional Space
Published on: February 1, 2016
Crystal-level timing calibration using cascaded photons of60Co point source for long axial animal PET system
Qing Wei1,2,3,4, Daowu Li1,3,4, Xianchao Huang1,3,4
1Beijing Engineering Research Centre of Radiographic Techniques and Equipment, Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049, People's Republic of China.
Abstract:
Objective.Timing calibration is essential for positron emission tomography (PET) system as it enhances timing resolution to improve image quality. Traditionally, positron sources are employed for timing calibration. However, the photons emitted by these sources travel in opposite directions, necessitating that positrons annihilate at multiple locations to collect coincidence data across a greater number of lines of response. To overcome this limitation, this study proposes a timing calibration method utilising a60Co point source.Approach.The60Co source emits cascaded photons without angular correlation, allowing the collection of coincidence events throughout the field of view (FOV) with a single60Co point source positioned at the centre of the FOV to determine the timing offsets of the pixels. Leveraging the properties of60Co, we propose a calibration method and implement it on a long axial animal PET system. Initially, we calibrated the timing offsets of the pixels within two blocks to establish reference detectors, and subsequently employed a60Co point source to determine the timing offsets of all the pixels in the system relative to these reference detectors. In addition, we evaluated the system's timing resolution before and after the calibration to validate the efficacy of the proposed method.Main results.We measured the timing offsets of the pixels across the entire system, ranging from -5.0 to 2.0 ns. After implementing the timing offset lookup table, the system timing resolution was improved from 6.30 ns before calibration to 1.04 ns.Significance. In this study, the60Co source is employed for timing calibration, offering the advantages of operational simplicity, broad applicability, and potential application in time-of-flight PET.
More Related Videos
10:21Continuous Blood Sampling in Small Animal Positron Emission Tomography/Computed Tomography Enables the Measurement of the Arterial Input Function
Published on: August 8, 2019
06:28Visualization of Low-Level Gamma Radiation Sources Using a Low-Cost, High-Sensitivity, Omnidirectional Compton Camera
Published on: January 30, 2020