Related Experiment Video
Updated: Jun 1, 2025

A Detailed Protocol for Perspiration Monitoring Using a Novel, Small, Wireless Device
Published on: November 24, 2016
Wearable ring sensor for monitoring biomarkers of atherosclerosis in sweat
Jie Fu1, Yanwen Wang1, Yihong Ding1
1Medical School of Tianjin University, Academy of Medical Engineering and Translational Medicine, Tianjin, 300072, China.
Abstract:
Atherosclerosis-induced cardiovascular diseases are a leading cause of disability and mortality worldwide. Currently, clinical diagnosis of atherosclerosis relies on analysis and assessment by large medical equipment and specialized professionals, involving invasive testing, which limits early detection and prognosis of atherosclerosis. Herein, this work develops a flexible wearable ring sensor for non-invasive real-time in situ monitoring of biomarkers associated with atherosclerosis. The device integrates electrochemical biosensing and microfluidic technology, utilizing screen-printing to create high-precision multi-channel electrodes. It can be worn on fingers to detect sweat flow rate and biomarkers including C-reactive protein (CRP), cholesterol, and potassium ions (K+), with the aim of improving disease management efficiency and enhancing patient experience. The synthesized ZIF-67@AuNPs was used as the signal amplification layer of the adapter sensor. The resulting sensor exhibites sensitive and linear responses within the concentration ranges of 0-100 ng mL-1 for CRP, 0-120 μM for cholesterol, and 10-6-1 M for K+. Further tests on specificity, reproducibility, and stability of the sensor confirm its potential for practical applications. In this work, the wearable ring sensor achieves accurate detection of atherosclerosis biomarkers in sweat samples, providing a new technological approach for non-invasive real-time monitoring that has the potential to contribute to early disease warning and personalized management.
Related Concept Videos
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...

