Related Experiment Video
Updated: May 6, 2026

Designing CAD/CAM Surgical Guides for Maxillary Reconstruction Using an In-house Approach
Published on: August 24, 2018
A study on the compressive strength of three-dimensional direct printing aligner material for specific designing of
Byeong Gu Bae1, Young Ho Kim1, Gun Ho Lee2
1Department of Orthodontics, Institute of Oral Health Science, Ajou University School of Medicine, Suwon, South Korea.
Background:
The demand for orthodontic treatment using clear aligners has been gradually increasing because of their superior esthetics compared with conventional fixed orthodontic therapy. This study aimed to evaluate and compare the compressive strength of three-dimensional direct printing aligners (3DPA) with that of conventional thermo-forming aligners (TFA) to determine their clinical applicability. In the experimental group, the 3DPA material TC-85 (TC-85 full) was used to create angular protrusions called rectangular pressure areas (RPA). A protrusion akin to the power ridge typically employed in conventional TFAs was created using glycol-modified polyethylene terephthalate (PETG; Control 1). RPA was created using the same TC-85 without filling the protrusions (TC-85 blank; Control 2). Compression cycle tests were conducted on an LTM 3 h electrodynamic testing machine (Zwick Roell, Germany), with 500 cycles and compression depths of 100, 300, 500, and 700 µm. Twenty specimens were tested for PETG, 17 for the TC-85 blank, and 19 for the TC-85 full.
Results:
Changes in the compressive force were assessed based on the material and thickness. The results indicated significantly higher and broader ranges of compressive strength for specimens fabricated with the 3DPA material TC-85 compared with those fabricated using PETG. Among the TC-85 specimens, TC-85 full demonstrated the highest statistically significant compressive strength .
Conclusions:
3DPA technology enables precise modifications in the shape and inner thickness at specific dental sites, including the creation of ridges in targeted areas, of aligners. These alterations enhance the biomechanical capability of aligners to exert selective forces necessary for desired tooth movement while reducing the number of attachments, thereby demonstrating the clinical potential of 3D-printed aligners in orthodontic treatment.
Related Concept Videos
Stress Concentrations
Stress Concentrations
The stress...
Yield Criteria for Ductile Materials under Plane Stress
The Maximum Shearing Stress Criterion, also known as...
Three-Dimensional Analysis of Strain
Stresses under Combined Loadings
The process begins by slicing the tube at critical points and analyzing the internal forces and stress components at these sections, focusing on the centroid. Normal stresses, generated by axial forces and bending moments, are either compressive or tensile and vary across the section from...
Mechanical Characteristics of Steel